1.INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve)
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 33 to 39 Ω |
| 1 - Body ground
2 - Body ground |
20°C (68°F) | 10 kΩ or higher |
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
| *1 | Port E |
| *2 | Filter |
|
Airflow |
Check the operation according to the value(s) in the table below.
Check that air flows from port E to the filter.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.
| *1 | Port E |
| *2 | Port F |
|
Airflow |
Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If the result is not as specified, replace the No. 1 vacuum switching valve assembly.