Home › Engine / Hybrid System › 1KD-FTV INTAKE / EXHAUST › VACUUM SWITCHING VALVE(for i-ART) › from 2012.04
RM1840EF _51 Engine / Hybrid System _009588 1KD-FTV INTAKE / EXHAUST _0052330 VACUUM SWITCHING VALVE(for i-ART) G

1KD-FTV INTAKE / EXHAUST  VACUUM SWITCHING VALVE(for i-ART)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT NO. 1 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 10 kΩ or higher


If the result is not as specified, replace the No. 1 vacuum switching valve assembly.


b.
G037162
2.938,0.833 2.844,0.833 2.844,0.833 2.458,1.125 true 0.802,0.958 0.896,0.958 0.896,0.958 1.115,1.115 false 1.448,0.375 1.521,0.292 false 1.51,0.323 1.573,0.26 false 2.958,0.729 3.24,0.979 0.281,0.25 10 false *2 0.635,0.844 0.938,1.073 0.302,0.229 10 false *1
*1 Port E
*2 Filter
V100135

Airflow


Check the operation according to the value(s) in the table below.

i.

Check that air flows from port E to the filter.

If the result is not as specified, replace the No. 1 vacuum switching valve assembly.


ii.
A110309
1.854,0.625 1.76,0.625 1.76,0.625 1.479,1.396 true 2.104,0.854 2.01,0.854 2.01,0.854 1.573,1.458 true 1.063,1.615 0.969,1.615 0.969,1.615 0.823,1.729 false 0.229,1.802 0.323,1.802 0.323,1.802 0.5,1.875 false 0.948,1.156 1.104,0.958 false 1.094,0.969 1.167,0.906 false 1.906,0.531 2.115,0.719 0.208,0.188 10 false *2 2.177,0.771 2.385,0.969 0.208,0.198 10 false *1 1.115,1.51 1.365,1.708 0.25,0.198 10 false *1 0.063,1.708 0.292,1.875 0.229,0.167 10 false *2
*1 Port E
*2 Port F
V100135

Airflow


Apply battery voltage across the terminals.


iii.

Check that air flows from port E to port F.

If the result is not as specified, replace the No. 1 vacuum switching valve assembly.



Hide 2.INSPECT NO. 2 VACUUM SWITCHING VALVE ASSEMBLY (for Swirl Control Valve)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground
2 - Body ground
20°C (68°F) 10 kΩ or higher


If the result is not as specified, replace the No. 2 vacuum switching valve assembly.


b.
G037162
2.938,0.833 2.844,0.833 2.844,0.833 2.458,1.125 true 0.802,0.958 0.896,0.958 0.896,0.958 1.115,1.115 false 1.448,0.375 1.521,0.292 false 1.51,0.323 1.573,0.26 false 2.958,0.729 3.24,0.979 0.281,0.25 10 false *2 0.635,0.844 0.938,1.073 0.302,0.229 10 false *1
*1 Port E
*2 Filter
V100135

Airflow


Check the operation according to the value(s) in the table below.

i.

Check that air flows from port E to the filter.

If the result is not as specified, replace the No. 2 vacuum switching valve assembly.


ii.
A110309
1.854,0.625 1.76,0.625 1.76,0.625 1.479,1.396 true 2.104,0.854 2.01,0.854 2.01,0.854 1.573,1.458 true 1.063,1.615 0.969,1.615 0.969,1.615 0.823,1.729 false 0.229,1.802 0.323,1.802 0.323,1.802 0.5,1.875 false 0.948,1.156 1.104,0.958 false 1.094,0.969 1.167,0.906 false 1.906,0.531 2.115,0.719 0.208,0.188 10 false *2 2.177,0.771 2.385,0.969 0.208,0.198 10 false *1 1.115,1.51 1.365,1.708 0.25,0.198 10 false *1 0.063,1.708 0.292,1.875 0.229,0.167 10 false *2
*1 Port E
*2 Port F
V100135

Airflow


Apply battery voltage across the terminals.


iii.

Check that air flows from port E to port F.