Home › Engine / Hybrid System › 1GR-FE INTAKE / EXHAUST › VACUUM SWITCHING VALVE(for ACIS) › from 2012.04
RM1840EF _51 Engine / Hybrid System _009592 1GR-FE INTAKE / EXHAUST _0052356 VACUUM SWITCHING VALVE(for ACIS) G

1GR-FE INTAKE / EXHAUST  VACUUM SWITCHING VALVE(for ACIS)  ON-VEHICLE INSPECTION  


PROCEDURE

Hide 1.INSPECT VACUUM SWITCHING VALVE ASSEMBLY (for ACIS)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 33 to 39 Ω
1 - Body ground Always 1 MΩ or higher
2 - Body ground


If the result is not as specified, replace the vacuum switching valve assembly.


b.

Check the VSV operation.

i.
B002276
2.448,1.104 2.448,1.375 false 2.354,1.417 2.531,1.635 0.177,0.219 10 false *1 1.25,1.125 1.406,1.323 0.156,0.198 10 true *2
*1 Filter
*2 Port E
V100135

Air


Check that air flows from port E to the filter.

If the result is not as specified, replace the vacuum switching valve assembly.


ii.
B002277
0.438,1.323 0.604,1.521 0.167,0.198 10 false *2 1.208,1.177 1.427,1.375 0.219,0.198 10 false *1
*1 Port E
*2 Port F
V100135

Air


Apply battery voltage across the terminals.


iii.

Check that air flows from port E to port F.

If the result is not as specified, replace the vacuum switching valve assembly.