Home › Drivetrain › A340F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM1840EF _52 Drivetrain _009609 A340F AUTOMATIC TRANSMISSION / TRANSAXLE _0052462 AUTOMATIC TRANSMISSION SYSTEM C

A340F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P0973  Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)  P0974  Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)  


DESCRIPTION

Shifting from 1st to 4th is performed in combination with the on and off operation of shift solenoid valves S1 and S2, which are controlled by the TCM. If an open or short circuit occurs in either of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely. Also, the TCM stops sending current to the open or short-circuited solenoid (See page Drivetrain>A340F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1) TCM detects a short in the solenoid valve S1 circuit 4 times when solenoid valve S1 is operated (1-trip detection logic).
·

Short in shift solenoid valve S1 circuit

·

Shift solenoid valve S1

·

TCM


Comes on DTC stored
P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1) TCM detects an open in the solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated (1-trip detection logic).
·

Open in shift solenoid valve S1 circuit

·

Shift solenoid valve S1

·

TCM


Comes on DTC stored

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in either shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve S1 is on, if its resistance is 8 Ω or less, the TCM determines there is a short in the shift solenoid valve S1 circuit.

When shift solenoid valve S1 is off, if its resistance is 100 kΩ or higher, the TCM determines there is an open in the shift solenoid valve S1 circuit (See page Drivetrain>A340F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>FAIL-SAFE CHART).

WIRING DIAGRAM

C214968
1.604,2.865 2.938,3.063 1.333,0.198 10 false Transmission Wire 1.604,2.688 2,2.885 0.396,0.198 10 false C12 5.615,1.219 6.115,1.417 0.5,0.198 10 false S1 5.313,1.344 5.667,1.552 0.354,0.208 10 false 18 5.813,2.906 6.313,3.104 0.5,0.198 10 false C24 5.813,3.083 6.313,3.281 0.5,0.198 10 false TCM 3.333,1.146 3.833,1.344 0.5,0.198 10 false S1 3.635,1.354 3.875,1.552 0.24,0.198 10 false 4 1.49,1.688 3.219,1.885 1.729,0.198 10 false Shift Solenoid Valve S1

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1)
a.
C214964
1.365,0.958 0.99,0.5 true 0.083,0.083 0.396,0.281 0.313,0.198 10 false *a 0.76,0.385 0.99,0.583 0.229,0.198 10 false S1
*a Component without harness connected
(Transmission Wire)


Disconnect the C12 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
4 (S1) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)

NG

3.INSPECT SHIFT SOLENOID VALVE S1
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
a.
C212047
0.813,0.292 1.198,0.563 0.385,0.271 0.906,2.063 0.635,2.844 true 0.094,0.073 0.292,0.24 0.198,0.167 10 false *a 0.865,0.344 1.167,0.5 0.302,0.156 10 false C24 0.417,2.875 0.917,3.052 0.5,0.177 10 false 18 (S1)
*a Rear view of wire harness connector
(to TCM)


Disconnect the C24 TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C24-18 (S1) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE S1
a.
C214962
0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 3.073,0.792 3.323,0.99 0.25,0.198 10 false (+) 3.083,0.188 3.292,0.385 0.208,0.198 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve S1)


Remove shift solenoid valve S1.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S1 connector

·

Battery negative (-) → Shift solenoid valve S1 body


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG