Home › Drivetrain › A340F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM1840EF _52 Drivetrain _009609 A340F AUTOMATIC TRANSMISSION / TRANSAXLE _0052462 AUTOMATIC TRANSMISSION SYSTEM C

A340F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

C237837
5.75,2.177 5.865,2.521 5.865,2.521 5.938,2.521 true 4.885,1.927 4.667,1.292 4.667,1.292 4.604,1.292 true 5.146,2.115 5.01,2.531 5.01,2.531 4.938,2.531 true 5.99,2.448 6.875,2.667 0.885,0.219 10 false Solenoid Coil 0.26,0.448 1.51,0.667 1.25,0.219 10 false Hydraulic Pressure 4.458,2.438 4.99,2.656 0.531,0.219 10 false Sleeve 3.833,1.198 4.677,1.417 0.844,0.219 10 false Spool Valve 2.75,2.979 3.313,3.198 0.563,0.219 10 false Current

Shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and vehicle speed sensor. The TCM adjusts the current of shift solenoid valve SLT to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

TCM


Comes on (w/ OBD)-(w/o OBD) DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the TCM interprets this as a fault. The TCM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

C214969
1.76,2.854 3.094,3.052 1.333,0.198 10 false Transmission Wire 1.76,2.677 2.156,2.875 0.396,0.198 10 false C12 5.604,1.24 6.104,1.438 0.5,0.198 10 false SLT+ 5.344,1.354 5.583,1.552 0.24,0.198 10 false 20 5.813,2.938 6.313,3.135 0.5,0.198 10 false C24 5.813,3.115 6.313,3.313 0.5,0.198 10 false TCM 3.469,1.146 3.969,1.344 0.5,0.198 10 false SLT+ 3.927,1.344 4.167,1.542 0.24,0.198 10 false 2 1.49,1.688 3.219,1.885 1.729,0.198 10 false Shift Solenoid Valve SLT 5.615,2.208 6.115,2.406 0.5,0.198 10 false SLT- 5.344,2.323 5.583,2.521 0.24,0.198 10 false 19 3.49,2.115 3.99,2.313 0.5,0.198 10 false SLT- 3.927,2.313 4.167,2.51 0.24,0.198 10 false 6 1.281,2.104 1.677,2.302 0.396,0.198 10 false 1 1.281,1.344 1.677,1.542 0.396,0.198 10 false 2

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
a.

Disconnect the C12 transmission wire connector.


b.
C214964
1.854,0.958 2.448,0.5 true 2.448,1.698 1.854,1.24 true 0.083,0.052 0.396,0.25 0.313,0.198 10 false *a 2.5,1.635 2.896,1.833 0.396,0.198 10 false SLT- 2.5,0.406 2.906,0.604 0.406,0.198 10 false SLT+
*a Component without harness connected
(Transmission Wire)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (SLT+) - 6 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
2 (SLT+) - Body ground Always 10 kΩ or higher
6 (SLT-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLT
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
a.
C212047
0.792,0.229 1.198,0.49 0.406,0.26 0.781,2.073 0.354,2.854 true 0.844,2.063 1.281,2.854 true 0.073,0.063 0.271,0.229 0.198,0.167 10 false *a 0.854,0.281 1.156,0.438 0.302,0.156 10 false C24 0.125,2.896 0.833,3.125 0.708,0.229 10 false 20 (SLT+) 1.063,2.896 1.688,3.115 0.625,0.219 10 false 19 (SLT-)
*a Rear view of wire harness connector
(to TCM)


Disconnect the C24 TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C24-20 (SLT+) - C24-19 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
C24-20 (SLT+) - Body ground Always 10 kΩ or higher
C24-19 (SLT-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLT
a.
C209928
1.771,0.969 2.219,0.385 true 1.458,0.969 1,0.385 true 1.771,2.948 2.219,2.354 true 1.469,2.948 1.01,2.354 true 0.073,0.083 0.385,0.281 0.313,0.198 10 false *a 2.25,0.25 2.417,0.448 0.167,0.198 10 false 1 0.875,0.271 1.042,0.469 0.167,0.198 10 false 2 2.24,2.188 2.406,2.385 0.167,0.198 10 false 1 0.917,2.188 1.083,2.385 0.167,0.198 10 false 2 1.906,3.948 2.167,4.198 0.26,0.25 10 false (-) 1.167,3.958 1.458,4.208 0.292,0.25 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SLT)


Remove shift solenoid valve SLT.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG