Home › Drivetrain › A343E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)
RM1840EF _52 Drivetrain _009610 A343E AUTOMATIC TRANSMISSION / TRANSAXLE _0052463 AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE) C

A343E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)  P0717  Turbine Speed Sensor Circuit No Signal  


DESCRIPTION

This sensor detects the rotation speed of the turbine which indicates the input speed of the transmission. By comparing the input turbine speed signal NC0 with the output speed sensor signal SP2, the ECM detects the shift timing of the gears and appropriately controls the engine torque and hydraulic pressure according to various conditions, and as a result, the gears shift smoothly.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0717 Turbine Speed Sensor Circuit No Signal All conditions are met for 5 seconds or more (1-trip detection logic):
(a) Transmission input shaft speed is 300 rpm or less.
(b) Transmission output shaft speed is 500 rpm or more.
(c) Park/neutral position switch R input signal is off.
·

Open or short in speed sensor NC0 circuit

·

Speed sensor NC0

·

ECM

·

Automatic transmission (clutch, brake, gear, etc.)


Comes on DTC stored

Reference: Inspect using an oscilloscope.

C170570
2.479,0.875 3.135,1.073 0.656,0.198 10 false 5 V/DIV. 2.573,1.635 2.99,1.833 0.417,0.198 10 false GND 1.531,2.615 2.49,2.802 0.958,0.188 10 false 0.5 msec./DIV.

Check the waveform of the ECM connector.

Standard:
Terminal No. (Symbol) Tool Setting Condition Specified Condition
C97-5 (NC0+) - C97-10 (NC0-) 5 V/DIV., 0.5 msec./DIV. Engine idling (shift lever in P or N) Refer to illustration


MONITOR DESCRIPTION

This DTC indicates that a pulse is not output from the speed sensor NC0 (turbine (input) speed sensor) or is output only a little. The NC0 terminal of the ECM detects the pulse signal from the speed sensor NC0 (input turbine speed). The ECM outputs a gear shift signal by comparing the input speed sensor NC0 signal with the output speed sensor SP2 signal.

If the input shaft speed is less than 300 rpm*1 although the output shaft speed is 500 rpm or more*2, the ECM detects the trouble, illuminates the MIL and stores the DTC.

HINT:
·

*1: A pulse is not output or is irregularly output.

·

*2: The vehicle speed is approximately 50 km/h (30 mph) or more.



WIRING DIAGRAM

C239151
5.656,1.146 6.135,1.354 0.479,0.208 10 false NC0+ 5.656,2.281 6.135,2.49 0.479,0.208 10 false NC0- 5.865,3.24 6.344,3.448 0.479,0.208 10 false ECM 5.865,3.052 6.198,3.26 0.333,0.208 10 false C97 0.563,2.542 1.938,2.74 1.375,0.198 10 false Speed Sensor NC0 0.563,2.354 0.865,2.552 0.302,0.198 10 false C11 5.344,2.354 5.573,2.563 0.229,0.208 10 false 10 5.417,1.229 5.646,1.438 0.229,0.208 10 false 5 1.281,1.281 1.417,1.49 0.135,0.208 10 false 2 1.281,2.073 1.427,2.281 0.146,0.208 10 false 1

CAUTION / NOTICE / HINT

DATA LIST


HINT:

Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the intelligent tester to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the intelligent tester on.


f.

Enter the following menus: Powertrain / Engine and ECT / Data List.


g.

According to the display on the tester, read the Data List.

Powertrain > Engine and ECT > Data List
Tester Display
SPD (NC0)
50003 234 394
Powertrain > Engine and ECT > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
SPD (NC0) Input shaft speed Min.: 0 rpm
Max.: 12750 rpm
·

Lock-up ON (after warming up engine): Input turbine speed (NC0) equal to engine speed

·

Lock-up OFF (idling with shift lever in N): Input turbine speed (NC0) nearly equal to engine speed


Data is displayed in increments of 50 rpm.
HINT:
·

SPD (NC0) is always 0 while driving:

Open or short in the sensor or circuit.

·

SPD (NC0) is always more than 0 and less than 300 rpm while driving the vehicle at 50 km/h (30 mph) or more:

Sensor trouble, improper installation, or intermittent connection trouble in the circuit.





PROCEDURE

1.INSPECT SPEED SENSOR NC0 INSTALLATION
a.
C211922
0.854,0.208 1.094,0.406 0.24,0.198 10 false *a 2.333,0.208 2.573,0.406 0.24,0.198 10 false *b
*a CORRECT
*b INCORRECT


Check the speed sensor NC0 installation.

OK:

The installation bolt is tightened properly and there is no clearance between the sensor and transmission case.



Result:
Proceed to
OK
NG



OK

2.INSPECT SPEED SENSOR NC0

NG

SECURELY INSTALL OR REPLACE SPEED SENSOR NC0

2.INSPECT SPEED SENSOR NC0
a.

Disconnect the C11 speed sensor connector.


b.
C206284
1.302,1.677 1.594,1.156 true 2.135,1.677 1.813,1.156 true 0.063,0.042 0.302,0.24 0.24,0.198 10 false *a 1.24,1.708 1.688,1.906 0.448,0.198 10 false 2 2.146,1.708 2.594,1.906 0.448,0.198 10 false 1
*a Component without harness connected
(Speed Sensor NC0)


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 560 to 680 Ω



Result:
Proceed to
OK
NG



OK

3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR NC0 - ECM)

NG

3.CHECK HARNESS AND CONNECTOR (SPEED SENSOR NC0 - ECM)
a.
C214337
2.167,0.292 2.552,0.552 0.385,0.26 1.75,2.688 2.208,1.917 true 2.677,2.667 2.25,1.969 true 0.073,0.052 0.302,0.25 0.229,0.198 10 false *a 1.49,2.719 2.167,2.917 0.677,0.198 10 false 5 (NC0+) 2.49,2.719 3.198,2.917 0.708,0.198 10 false 10 (NC0-) 2.229,0.344 2.604,0.573 0.375,0.229 10 false C97
*a Rear view of wire harness connector
(to ECM)


Disconnect the C97 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C97-5 (NC0+) - C97-10 (NC0-) 20°C (68°F) 560 to 680 Ω
C97-5 (NC0+) - Body ground Always 10 kΩ or higher
C97-10 (NC0-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR