Shifting from 1st to 4th is performed in combination with the on and off operation of shift solenoid valves S1 and S2, which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely. Also, the ECM stops sending current to the open or short-circuited solenoid (See page Drivetrain>A343E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)>FAIL-SAFE CHART).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0973 | Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1) | ECM detects a short in the solenoid valve S1 circuit 4 times when solenoid valve S1 is operated (1-trip detection logic). | ·
Short in shift solenoid valve S1 circuit ·
Shift solenoid valve S1 ·
ECM |
Comes on | DTC stored |
| P0974 | Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1) | ECM detects an open in the solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated (1-trip detection logic). | ·
Open in shift solenoid valve S1 circuit ·
Shift solenoid valve S1 ·
ECM |
Comes on | DTC stored |
These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in either shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores the DTC. When shift solenoid valve S1 is on, if its resistance is 8 Ω or less, the ECM determines there is a short in the shift solenoid valve S1 circuit.
When shift solenoid valve S1 is off, if its resistance is 100 kΩ or higher, the ECM determines there is an open in the shift solenoid valve S1 circuit (See page Drivetrain>A343E AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)>FAIL-SAFE CHART).
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the C92 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (S1) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Disconnect the C96 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C96-21 (S1) - Body ground | 20°C (68°F) | 11 to 15 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Shift Solenoid Valve S1) |
Remove shift solenoid valve S1.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body | 20°C (68°F) | 11 to 15 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) → Shift solenoid valve S1 connector ·
Battery negative (-) → Shift solenoid valve S1 body |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG