Home › Drivetrain › A343E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)
RM1840EF _52 Drivetrain _009610 A343E AUTOMATIC TRANSMISSION / TRANSAXLE _0052463 AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE) C

A343E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)  P2716  Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)  


DESCRIPTION

C237837
5.977,2.373 6.862,2.588 0.885,0.215 10 Solenoid Coil 0.257,0.446 1.508,0.661 1.251,0.215 10 Hydraulic Pressure 4.459,2.373 4.992,2.588 0.533,0.215 10 Sleeve 3.831,1.17 4.669,1.385 0.839,0.215 10 Spool Valve 5.741,2.122 5.859,2.465 5.859,2.465 5.926,2.465 false 2.746,2.974 3.311,3.189 0.565,0.215 10 Current 4.909,1.901 4.688,1.26 4.688,1.26 4.621,1.26 false 5.151,2.054 5.009,2.465 5.009,2.465 4.942,2.465 false

Shift solenoid valve SLT controls the transmission line pressure for smooth transmission operation based on signals from the throttle position sensor and vehicle speed sensor. The ECM adjusts the current of shift solenoid valve SLT to control the hydraulic line pressure coming from the primary regulator valve. Appropriate line pressure assures smooth shifting with varying engine outputs.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
·

Open or short in shift solenoid valve SLT circuit

·

Shift solenoid valve SLT

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will illuminate the MIL and store the DTC.

WIRING DIAGRAM

C214969
1.76,2.875 3.094,3.073 1.333,0.198 10 false Transmission Wire 1.76,2.698 2.156,2.896 0.396,0.198 10 false C92 5.615,1.25 6.115,1.448 0.5,0.198 10 false SLT+ 5.323,1.365 5.563,1.563 0.24,0.198 10 false 23 5.813,2.938 6.313,3.135 0.5,0.198 10 false C96 5.813,3.104 6.313,3.302 0.5,0.198 10 false ECM 3.469,1.135 3.969,1.333 0.5,0.198 10 false SLT+ 3.948,1.365 4.188,1.563 0.24,0.198 10 false 2 1.49,1.719 3.219,1.917 1.729,0.198 10 false Shift Solenoid Valve SLT 5.615,2.208 6.115,2.406 0.5,0.198 10 false SLT- 5.333,2.323 5.573,2.521 0.24,0.198 10 false 24 3.479,2.104 3.979,2.302 0.5,0.198 10 false SLT- 3.938,2.313 4.177,2.51 0.24,0.198 10 false 6 1.281,2.115 1.677,2.313 0.396,0.198 10 false 1 1.281,1.344 1.677,1.542 0.396,0.198 10 false 2

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
a.
C214964
1.844,0.958 2.438,0.5 true 2.448,1.698 1.854,1.24 true 0.063,0.073 0.375,0.271 0.313,0.198 10 false *a 2.5,1.646 2.896,1.844 0.396,0.198 10 false SLT- 2.5,0.417 2.906,0.615 0.406,0.198 10 false SLT+
*a Component without harness connected
(Transmission Wire)


Disconnect the C92 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (SLT+) - 6 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
2 (SLT+) - Body ground Always 10 kΩ or higher
6 (SLT-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SLT
2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
a.
C214336
1.792,0.292 2.156,0.563 0.365,0.271 1.438,2.677 1.854,2.104 true 2.333,2.667 1.906,2.094 true 0.052,0.052 0.323,0.25 0.271,0.198 10 false *a 1.083,2.719 1.75,2.917 0.667,0.198 10 false 24 (SLT-) 2.083,2.719 2.771,2.917 0.688,0.198 10 false 23 (SLT+) 1.854,0.344 2.229,0.573 0.375,0.229 10 false C96
*a Rear view of wire harness connector
(to ECM)


Disconnect the C96 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C96-23 (SLT+) - C96-24 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω
C96-23 (SLT+) - Body ground Always 10 kΩ or higher
C96-24 (SLT-) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SLT
a.
C209928
1.76,0.958 2.208,0.375 true 1.479,0.979 1.021,0.396 true 1.76,2.948 2.208,2.354 true 1.469,2.958 1.01,2.365 true 0.073,0.073 0.385,0.271 0.313,0.198 10 false *a 2.24,0.229 2.406,0.427 0.167,0.198 10 false 1 0.917,0.26 1.083,0.458 0.167,0.198 10 false 2 2.24,2.208 2.406,2.406 0.167,0.198 10 false 1 0.917,2.219 1.083,2.417 0.167,0.198 10 false 2 1.927,3.958 2.125,4.156 0.198,0.198 10 false (-) 1.115,3.958 1.333,4.156 0.219,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SLT)


Remove shift solenoid valve SLT.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG