Home › Drivetrain › A343E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)
RM1840EF _52 Drivetrain _009610 A343E AUTOMATIC TRANSMISSION / TRANSAXLE _0052463 AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE) C

A343E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 2TR-FBE)  P2769  Torque Converter Clutch Solenoid Circuit Low (Shift Solenoid Valve SL)  P2770  Torque Converter Clutch Solenoid Circuit High (Shift Solenoid Valve SL)  


DESCRIPTION

The shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls the operation of the lock-up clutch.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P2769 Torque Converter Clutch Solenoid Circuit Low (Shift Solenoid Valve SL) ECM detects short in shift solenoid valve SL circuit (once) when shift solenoid valve SL is operated (2-trip detection logic)
·

Short in shift solenoid valve SL circuit

·

Shift solenoid valve SL

·

ECM


Comes on DTC stored
P2770 Torque Converter Clutch Solenoid Circuit High (Shift Solenoid Valve SL) ECM detects open in shift solenoid valve SL circuit (once) when shift solenoid valve SL is not operated (2-trip detection logic)
·

Open in shift solenoid valve SL circuit

·

Shift solenoid valve SL

·

ECM


Comes on DTC stored

Fail-safe function:

If the ECM detects a malfunction, it turns the shift solenoid valve SL off.

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on engine speed, engine load, engine temperature, vehicle speed, transmission temperature, and shift position selection. The ECM determines the lock-up status of the torque converter by comparing the engine speed (NE) to the input speed (NC0). The ECM calculates the actual transmission gear by comparing the input speed (NC0) to the output speed (SP2). When conditions are appropriate, the ECM requests "lock-up" by applying control voltage to the shift solenoid valve SL. When the shift solenoid valve SL is opened, the shift solenoid valve SL applies pressure to the lock-up relay valve and locks the torque converter. If the ECM detects an open or short in the shift solenoid valve SL circuit, the ECM interprets this as a fault in the shift solenoid valve SL or its circuit. The ECM will illuminate the MIL and store a DTC.

WIRING DIAGRAM

C237838
2.49,0.896 2.75,1.104 0.26,0.208 10 false SL 5.74,1 6,1.208 0.26,0.208 10 false SL 1.01,1.74 2.521,1.948 1.51,0.208 10 false Shift Solenoid Valve SL 0.938,2.969 2.448,3.177 1.51,0.208 10 false Transmission Wire 0.927,2.792 1.271,2.979 0.344,0.188 10 false C92 5.969,3.292 6.365,3.5 0.396,0.208 10 false ECM 5.969,3.115 6.26,3.302 0.292,0.188 10 false C96 2.813,1.135 3.031,1.344 0.219,0.208 10 false 7 5.438,1.135 5.656,1.344 0.219,0.208 10 false 19

PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)
a.
C214964
1.063,1.708 1.542,1.219 true 0.063,0.042 0.375,0.24 0.313,0.198 10 false *a 0.875,1.729 1.104,1.927 0.229,0.198 10 false SL
*a Component without harness connected
(Transmission Wire)


Disconnect the C92 transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
7 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL - ECM)

NG

3.INSPECT SHIFT SOLENOID VALVE SL
2.CHECK HARNESS AND CONNECTOR (SHIFT SOLENOID VALVE SL - ECM)
a.
C214336
1.823,0.302 2.146,0.542 0.323,0.24 2.323,2.667 2.115,2.094 true 0.073,0.063 0.354,0.26 0.281,0.198 10 false *a 2.167,2.688 2.708,2.885 0.542,0.198 10 false 19 (SL) 1.854,0.344 2.229,0.573 0.375,0.229 10 false C96
*a Rear view of wire harness connector
(to ECM)


Disconnect the C96 ECM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C96-19 (SL) - Body ground 20°C (68°F) 11 to 15 Ω



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS AND CONNECTOR

3.INSPECT SHIFT SOLENOID VALVE SL
a.
C237973
0.083,0.073 0.333,0.292 0.25,0.219 10 false *a 3.052,0.5 3.292,0.719 0.24,0.219 10 false (+) 3.063,1.115 3.302,1.333 0.24,0.219 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve SL)


Remove shift solenoid valve SL.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SL connector terminal - Shift solenoid valve SL body 20°C (68°F) 11 to 15 Ω



c.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SL connector

·

Battery negative (-) → Shift solenoid valve SL body


Valve moves and makes an operating noise



Result:
Proceed to
OK
NG



OK

NG