The Park/Neutral Position (PNP) switch detects the shift lever position and sends signals to the ECM.
| *a | Front view of wire harness connector
(to Park/Neutral Position Switch) |
Disconnect the park/neutral position switch connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C26-2 (RB) - Body ground | Ignition switch ON | 11 to 14 V |
| C26-2 (RB) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Park/Neutral Position Switch) |
Disconnect the park/neutral position switch connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| C26-4 (B) - Body ground | Ignition switch ON | 11 to 14 V |
| C26-4 (B) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Park/Neutral Position Switch) |
Disconnect the park/neutral position switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 4 (B) - 5 (L) | Shift lever in P | Below 1 Ω |
| 2 (RB) - 1 (RL) | Shift lever in R | Below 1 Ω |
| 4 (B) - 5 (L) | Shift lever in N | Below 1 Ω |
| 2 (RB) - 7 (DL) | Shift lever in D or 3 | Below 1 Ω |
| 2 (RB) - 3 (2L) | Shift lever in 2 | Below 1 Ω |
| 2 (RB) - 8 (LL) | Shift lever in L | Below 1 Ω |
| 4 (B) - 5 (L) | Shift lever not in P | 10 kΩ or higher |
| 2 (RB) - 1 (RL) | Shift lever not in R | 10 kΩ or higher |
| 4 (B) - 5 (L) | Shift lever not in N | 10 kΩ or higher |
| 2 (RB) - 7 (DL) | Shift lever not in D or 3 | 10 kΩ or higher |
| 2 (RB) - 3 (2L) | Shift lever not in 2 | 10 kΩ or higher |
| 2 (RB) - 8 (LL) | Shift lever not in L | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereDrivetrain>A343E AUTOMATIC TRANSMISSION / TRANSAXLE>PARK / NEUTRAL POSITION SWITCH>REMOVAL
| *a | Component without harness connected
(Shift Lock Control ECU) |
Disconnect the shift lock control ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (AT3) - 9 (NSSD) | Shift lever in 3 | Below 1 Ω |
| 3 (AT3) - 9 (NSSD) | Shift lever in D | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector
(to Shift Lock Control ECU) |
Disconnect the shift lock control ECU connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 9 (NSSD) - Body ground | ·
Ignition switch ON ·
Shift lever in D or 3 |
11 to 14 V |
| 9 (NSSD) - Body ground | ·
Ignition switch ON ·
Shift lever not in D or 3 |
Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to ECM) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G88-11 (R) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever in R |
11 to 14 V* |
| G88-19 (3) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever in 3 |
11 to 14 V |
| G88-10 (2) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever in 2 |
11 to 14 V |
| G88-9 (L) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever in L |
11 to 14 V |
| G88-11 (R) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever not in R |
Below 1 V |
| G88-19 (3) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever not in 3 |
Below 1 V |
| G88-10 (2) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever not in 2 |
Below 1 V |
| G88-9 (L) - C75-3 (E1) | ·
Ignition switch ON ·
Shift lever not in L |
Below 1 V |
*: The voltage will drop slightly due to the illumination of the back-up light.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the C26 park/neutral position switch connector.
Disconnect the G89 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C26-4 (B) - G89-30 (NSW) | Always | Below 1 Ω |
| C26-4 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG