CHECK ECM
The standard voltage at each ECM terminal is shown in the table below.
In the table, first follow the information under "Condition". Look under "Terminal No. (Symbol)" for the terminals to inspect. The standard voltage between the terminals is shown under "Specified Condition".
Use the illustration above as a reference for the ECM terminals.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| C131-13 (L4) - C131-1 (E1) | G-W - BR | Transfer L4 position signal | ·
Ignition switch ON ·
Transfer shift lever in L4 |
Below 1 V |
·
Ignition switch ON ·
Transfer shift lever not in L4 |
11 to 14 V | |||
| C130-25 (TFN) - C131-1 (E1) | W-G - BR | Transfer Neutral position signal | ·
Ignition switch ON ·
Transfer shift lever in N |
Below 1 V |
·
Ignition switch ON ·
Transfer shift lever not in N |
11 to 14 V | |||
| C130-8 (NSW) - C131-1 (E1) | L-Y - BR | PNP switch signal | ·
Ignition switch ON ·
Shift lever in P or N |
Below 1 V |
·
Ignition switch ON ·
Shift lever not in P or N |
11 to 14 V | |||
| G154-11 (R) - C131-1 (E1) | R-Y - BR | R shift position switch signal | ·
Ignition switch ON ·
Shift lever in R |
11 to 14 V |
·
Ignition switch ON ·
Shift lever not in R |
Below 1 V | |||
| G154-21 (D) - C131-1 (E1) | G-Y - BR | D shift position switch signal | ·
Ignition switch ON ·
Shift lever in D or 4 |
11 to 14 V |
·
Ignition switch ON ·
Shift lever not in D or 4 |
Below 1 V | |||
| G154-20 (4) - C131-1 (E1) | G-O - BR | 4 shift position switch signal | ·
Ignition switch ON ·
Shift lever in 4 |
11 to 14 V |
·
Ignition switch ON ·
Shift lever not in 4 |
Below 1 V | |||
| G154-19 (3) - C131-1 (E1) | L - BR | 3 shift position switch signal | ·
Ignition switch ON ·
Shift lever in 3 |
11 to 14 V |
·
Ignition switch ON ·
Shift lever not in 3 |
Below 1 V | |||
| G154-10 (2) - C131-1 (E1) | G-R - BR | 2 shift position switch signal | ·
Ignition switch ON ·
Shift lever in 2 or L |
11 to 14 V |
·
Ignition switch ON ·
Shift lever not in 2 or L |
Below 1 V | |||
| G154-9 (L) - C131-1 (E1) | GR-L - BR | L shift position switch signal | ·
Ignition switch ON ·
Shift lever in L |
11 to 14 V |
·
Ignition switch ON ·
Shift lever not in L |
Below 1 V | |||
| C130-11 (S1) - C131-1 (E1) | GR - BR | S1 solenoid signal | 1st or 2nd gear | 11 to 14 V |
| 3rd, 4th or 5th gear | Below 1 V | |||
| C130-10 (S2) - C131-1 (E1) | W-L - BR | S2 solenoid signal | 2nd or 3rd gear | 11 to 14 V |
| 1st, 4th or 5th gear | Below 1 V | |||
| C130-9 (SR) - C131-1 (E1) | G - BR | SR solenoid signal | 5th gear | 11 to 14 V |
| 1st gear | Below 1 V | |||
| C130-19 (SL1+) - C130-18 (SL1-) | G-W - P-L | SL1 solenoid signal | Engine idling | Pulse generation |
| C130-17 (SL2+) - C130-16 (SL2-) | G-B - G-R | SL2 solenoid signal | Engine idling | Pulse generation |
| C130-13 (SLT+) - C130-12 (SLT-) | G-Y - L-B | SLT solenoid signal | Engine idling | Pulse generation |
| C130-15 (SLU+) - C130-14 (SLU-) | L - W | SLU solenoid signal | 5th gear (lock-up) | Pulse generation |
| C130-24 (THO1) - C129-28 (E2) | W-R - BR | No. 1 ATF temperature sensor signal | No. 1 ATF temperature 115°C (239°F) or higher | Below 1.5 V |
| C130-32 (THO2) - C129-28 (E2) | B-Y - BR | No. 2 ATF temperature sensor signal | No. 2 ATF temperature 115°C (239°F) or higher | Below 1.5 V |
| C130-34 (SP2+) - C130-26 (SP2-) | V - P | Speed sensor SP2 signal | Vehicle speed 20 km/h (12 mph) | Pulse generation
(See waveform 1) |
| C130-35 (NT+) - C130-27 (NT-) | L - Y | Speed sensor NT signal | Engine idling
(shift lever in P or N) |
Pulse generation
(See waveform 2) |
Using an oscilloscope, check waveform 1.
| Terminal No. (Symbol) | Tool Setting | Condition |
|---|---|---|
| C130-34 (SP2+) - C130-26 (SP2-) | 2 V/DIV., 20 msec./DIV. | Vehicle speed 20 km/h (12 mph) |
Using an oscilloscope, check waveform 2.
| Terminal No. (Symbol) | Tool Setting | Condition |
|---|---|---|
| C130-35 (NT+) - C130-27 (NT-) | 1 V/DIV., 2 msec./DIV. | Engine idling (shift lever in P or N) |