Home › Drivetrain › A750F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM(for 1KD-FTV with i-ART) › from 2012.04
RM1840EF _52 Drivetrain _009612 A750F AUTOMATIC TRANSMISSION / TRANSAXLE _0052493 AUTOMATIC TRANSMISSION SYSTEM(for 1KD-FTV with i-ART) C

A750F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM(for 1KD-FTV with i-ART)  P0712  Transmission Fluid Temperature Sensor "A" Circuit Low Input  P0713  Transmission Fluid Temperature Sensor "A" Circuit High Input  


DESCRIPTION

The ATF (Automatic Transmission Fluid) temperature sensor converts the ATF temperature into a resistance value which is input into the TCM.

The TCM applies a voltage to the temperature sensor through TCM terminal THO1.

The sensor resistance changes with the ATF temperature.

One terminal of the sensor is grounded so that the sensor resistance and voltage decrease as the temperature becomes higher.

The TCM calculates the ATF temperature based on the voltage signal.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Memory
P0712 Transmission Fluid Temperature Sensor "A" Circuit Low Input ATF temperature sensor resistance is below 79 Ω for 0.5 sec. or more (1-trip detection logic).
·

Short in No. 1 ATF temperature sensor circuit

·

No. 1 ATF temperature sensor (transmission wire)

·

TCM


Comes on DTC stored
P0713 Transmission Fluid Temperature Sensor "A" Circuit High Input ATF temperature sensor resistance is higher than 156 kΩ for 0.5 sec. or more and either condition is met (1-trip detection logic):
(A) 550 sec. or more have elapsed after the engine start when the engine coolant temperature or intake air temperature is -29.375°C (-20.875°F) or less.
(B) 10 sec. or more have elapsed after the engine start when the engine coolant temperature and intake air temperature are higher than -29.375°C (-20.875°F).
·

Open in No. 1 ATF temperature sensor circuit

·

No. 1 ATF temperature sensor (transmission wire)

·

TCM


Comes on DTC stored

MONITOR DESCRIPTION

The ATF temperature sensor converts the ATF temperature to an electrical resistance value. Based on the resistance, the TCM determines the ATF temperature and detects an open or short in the ATF temperature sensor circuit. If the resistance value of the ATF temperature sensor is below 79 Ω*1 or higher than 156 kΩ*2, the TCM interprets this as a fault in the ATF temperature sensor or wiring. The TCM will illuminate the MIL and store the DTC.

HINT:
·

*1: 150°C (302°F) or higher is indicated regardless of the actual ATF temperature.

·

*2: -40°C (-40°F) is indicated regardless of the actual ATF temperature.

·

The ATF temperature can be checked on the GTS display.



WIRING DIAGRAM

C155188E37
5.479,1.219 5.948,1.417 0.469,0.198 10 false THO1 5.198,1.333 5.5,1.531 0.302,0.198 10 false 25 5.198,2.479 5.5,2.677 0.302,0.198 10 false 24 3.51,1.313 3.813,1.51 0.302,0.198 10 false 10 3.51,2.469 3.813,2.667 0.302,0.198 10 false 9 1.073,1.323 1.24,1.521 0.167,0.198 10 false 2 5.188,3.844 5.49,4.042 0.302,0.198 10 false 23 5.49,2.375 5.958,2.573 0.469,0.198 10 false THO2 3.063,2.219 3.49,2.417 0.427,0.198 10 false OT2+ 1.292,1.083 1.76,1.281 0.469,0.198 10 false OT- 1.292,2.24 1.76,2.438 0.469,0.198 10 false OT2- 5.5,3.719 5.969,3.917 0.469,0.198 10 false E2 5.771,4.25 6.24,4.448 0.469,0.198 10 false C24 5.781,4.427 6.25,4.625 0.469,0.198 10 false TCM 1.76,3.177 2.229,3.375 0.469,0.198 10 false C151 1.76,3.365 3.063,3.563 1.302,0.198 10 false Transmission Wire 1.396,1.563 3.417,1.76 2.021,0.198 10 false No. 1 ATF Temperature Sensor 1.406,2.708 3.427,2.906 2.021,0.198 10 false No. 2 ATF Temperature Sensor 1.063,2.479 1.229,2.677 0.167,0.198 10 false 1 3.135,1.073 3.49,1.271 0.354,0.198 10 false OT+

CAUTION / NOTICE / HINT

DATA LIST


HINT:

Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.


NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the GTS to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the GTS on.


f.

Enter the following menus: Powertrain / ECT / Data List.


g.

According to the display on the GTS, read the Data List.

Powertrain > ECT > Data List
Tester Display
A/T Oil Temperature 1
50003 64 177
Powertrain > ECT > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note
A/T Oil Temperature 1 No. 1 ATF temperature sensor value Min.: -40°C (-40°F)
Max.: 150°C (302°F)
·

After stall test: Approx. 80°C (176°F)

·

Equal to ambient temperature after cold soak


If the value is "-40°C (-40°F)" or "150°C (302°F)", the No. 1 ATF temperature sensor circuit is open or shorted.
HINT:

When DTC P0712 is output and the GTS output is 150°C (302°F) or higher, there is a short circuit.

When DTC P0713 is output and the GTS output is -40°C (-40°F), there is an open circuit.

Check the temperature displayed on the GTS in order to check if a malfunction exists.


Temperature Displayed Malfunction
-40°C (-40°F) Open circuit
150°C (302°F) or higher Short circuit



PROCEDURE

1.INSPECT TRANSMISSION WIRE (NO. 1 ATF TEMPERATURE SENSOR)
a.
C214326C49
1.979,1.313 1.792,1.74 true 2.094,1.115 2.323,1.74 true 1.604,1.76 1.938,1.938 0.333,0.177 10 false OT+ 0.052,0.021 0.281,0.188 0.229,0.167 10 false *a 2.24,1.75 2.573,1.917 0.333,0.167 10 false OT-
*a Component without harness connected
(Transmission Wire)


Disconnect the transmission wire connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (OT-) - 10 (OT+) Always 79 Ω to 156 kΩ
2 (OT-) - Body ground Always 10 kΩ or higher
10 (OT+) - Body ground Always 10 kΩ or higher


HINT:

If the resistance is out of the specified range at one of the ATF temperatures shown in the table below, the driveability of the vehicle may decrease.


Resistance (Reference):
ATF Temperature Specified Condition
10°C (50°F) 5 to 8 kΩ
25°C (77°F) 2.5 to 4.5 kΩ
110°C (230°F) 0.22 to 0.28 kΩ



Result:
Proceed to
OK
NG



OK

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)

NG

REPAIR OR REPLACE NO. 1 ATF TEMPERATURE SENSOR (TRANSMISSION WIRE)

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM)
a.
C212047C24
0.813,0.313 1.198,0.583 0.385,0.271 0.698,2.781 1.208,2.177 true 1.677,2.813 1.354,2.167 true 0.375,2.844 1.292,3.042 0.917,0.198 10 false 25 (THO1) 1.469,2.844 2.385,3.042 0.917,0.198 10 false 23 (E2) 0.083,0.104 0.396,0.302 0.313,0.198 10 false *a 0.875,0.365 1.375,0.563 0.5,0.198 10 false C24
*a Rear view of wire harness connector
(to TCM)


Disconnect the TCM connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C24-25 (THO1) - C24-23 (E2) Always 79 Ω to 156 kΩ
C24-25 (THO1) - Body ground Always 10 kΩ or higher
C24-23 (E2) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR