A750F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT SOLENOID VALVE SR

C214329
0.094,0.063 0.344,0.26 0.25,0.198 10 false *a 1.76,0.281 1.948,0.479 0.188,0.198 10 false (-) 2.417,0.281 2.667,0.479 0.25,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve SR)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve SR connector

·

Battery negative (-) → Shift solenoid valve SR body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 2.INSPECT SHIFT SOLENOID VALVE SLU AND SLT

C209928
1.75,0.99 2.188,0.417 true 1.49,0.99 1.031,0.417 true 1.75,2.969 2.198,2.385 true 1.479,2.979 1.031,2.396 true 0.083,0.063 0.396,0.26 0.313,0.198 10 false *a 2.219,0.26 2.385,0.458 0.167,0.198 10 false 1 0.927,0.26 1.094,0.458 0.167,0.198 10 false 2 2.229,2.24 2.396,2.438 0.167,0.198 10 false 1 0.927,2.24 1.094,2.438 0.167,0.198 10 false 2 1.896,3.948 2.094,4.146 0.198,0.198 10 false (-) 1.177,3.948 1.396,4.146 0.219,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 2

·

Battery negative (-) → Terminal 1


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 3.INSPECT SHIFT SOLENOID VALVE SL1 AND SL2

C197715
1.75,1 2.198,0.417 true 1.49,1 1.031,0.417 true 1.74,2.99 2.188,2.396 true 1.49,2.99 1.031,2.396 true 0.094,0.063 0.406,0.26 0.313,0.198 10 false *a 2.229,0.25 2.396,0.448 0.167,0.198 10 false 1 0.927,0.25 1.094,0.448 0.167,0.198 10 false 2 2.229,2.24 2.396,2.438 0.167,0.198 10 false 1 0.927,2.24 1.094,2.438 0.167,0.198 10 false 2 1.885,3.948 2.115,4.146 0.229,0.198 10 false (+) 1.219,3.958 1.448,4.156 0.229,0.198 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) with a 21 W bulb → Terminal 1

·

Battery negative (-) → Terminal 2


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 4.INSPECT SHIFT SOLENOID VALVE S1

C214327
0.094,0.073 0.333,0.271 0.24,0.198 10 false *a 2.5,0.292 2.76,0.469 0.26,0.177 10 false (+) 3.188,0.292 3.396,0.479 0.208,0.188 10 false (-)
*a Component without harness connected
(Shift Solenoid Valve S1)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S1 connector

·

Battery negative (-) → Shift solenoid valve S1 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 5.INSPECT SHIFT SOLENOID VALVE S2

C214328
0.094,0.083 0.344,0.281 0.25,0.198 10 false *a 1.802,0.271 2,0.469 0.198,0.198 10 false (-) 2.469,0.271 2.698,0.469 0.229,0.198 10 false (+)
*a Component without harness connected
(Shift Solenoid Valve S2)


a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V of battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
·

Battery positive (+) → Shift solenoid valve S2 connector

·

Battery negative (-) → Shift solenoid valve S2 body


Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.