The amount of current flow to the solenoid is controlled by the current of the TCM output signal. During the lock-up operation, if the current increases, the lock-up hydraulic pressure increases.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P2759 | Torque Converter Clutch Pressure Control Solenoid Control Circuit Electrical (Shift Solenoid Valve SLU) | Open or short is detected in the shift solenoid valve SLU circuit for 1 sec. or more while driving (1-trip detection logic). | ·
Open or short in shift solenoid valve SLU circuit ·
Shift solenoid valve SLU ·
TCM |
Comes on | DTC stored |
When an open or short in the shift solenoid valve SLU circuit is detected, the TCM determines there is a malfunction. The TCM will turn on the MIL and store this DTC.
| *a | Component without harness connected
(Transmission Wire) |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 13 (SLU+) - 5 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 13 (SLU+) - Body ground | Always | 10 kΩ or higher |
| 5 (SLU-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Rear view of wire harness connector
(to TCM) |
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C24-22 (SLU+) - C24-21 (SLU-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| C24-22 (SLU+) - Body ground | Always | 10 kΩ or higher |
| C24-21 (SLU-) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component without harness connected
(Shift Solenoid Valve SLU) |
Remove shift solenoid valve SLU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
| Measurement Condition | Specified Condition |
|---|---|
·
Battery positive (+) with a 21 W bulb → Terminal 2 ·
Battery negative (-) → Terminal 1 |
Valve moves and makes an operating noise |
| Proceed to |
|---|
| OK |
| NG |
OK
NG