Home › Power Source / Network › 2KD-FTV BATTERY / CHARGING › GENERATOR(for BOSCH Made)
RM1840EF _57 Power Source / Network _009634 2KD-FTV BATTERY / CHARGING _0052667 GENERATOR(for BOSCH Made) G

2KD-FTV BATTERY / CHARGING  GENERATOR(for BOSCH Made)  INSPECTION  


PROCEDURE

Hide 1.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A117277

Check the rotor for an open circuit.

i.

Measure the resistance between the slip rings.

Standard resistance:

1.8 to 2.8 Ω at 20°C (68°F)


If the result is not as specified, replace the rotor assembly.



b.
A117278

Check if the rotor is grounded.

i.

Measure the resistance between each slip ring and the rotor.

Standard resistance:

10 kΩ or higher


If the result is not as specified, replace the rotor assembly.



c.

Check that the slip rings are not rough or scored.

If rough or scored, replace the rotor assembly.


d.
A117279

Using a vernier caliper, measure the diameter of each slip ring.

Standard diameter:

15.3 to 15.5 mm (0.602 to 0.610 in.)


Minimum diameter:

14.9 mm (0.587 in.)


If the diameter is less than the minimum, replace the rotor assembly.


Hide 2.INSPECT GENERATOR STATOR SUB-ASSEMBLY WITH RECTIFIER

A265112
1.333,1.615 1.406,1.552 false
V100135

Positive (+) Terminal
V100136

Negative (-) Terminal
V100137

Rectifier Terminal


HINT:

For terminal positions of the generator stator, refer to the illustration above.


a.
A117281

Inspect the positive (+) rectifier.

HINT:

Inspect the positive terminal after pulling it up.


i.

Using an ohmmeter, connect one tester probe to each positive (+) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.

If the result is not as specified, replace the generator stator sub-assembly with rectifier.



b.
A117282

Inspect the negative (-) rectifier.

i.

Using an ohmmeter, connect one tester probe to each negative (-) terminal and the other to each rectifier terminal.


ii.

Reverse the polarity of the tester probes and repeat the step above.


iii.

Check that one polarity shows a resistance of below 1 Ω and the other shows a resistance of 10 kΩ or higher.

If the result is not as specified, replace the generator stator sub-assembly with rectifier.



c.
A117283

Inspect the stator coil for an open circuit.

i.

Measure the resistance between the rectifier terminals.

Standard resistance:

Below 1 Ω


If the result is not as specified, replace the generator stator sub-assembly with rectifier.



Hide 3.INSPECT BRUSH

A117284
0.844,0.333 1.031,0.531 0.188,0.198 10 false *a
*a Length


a.

Using a vernier caliper, measure the exposed brush length.

Standard exposed length of new brush:

13.2 mm (0.520 in.)


Minimum exposed length:

6.0 mm (0.236 in.)


If the exposed length is less than the minimum, replace the generator regulator assembly.


Hide 4.INSPECT GENERATOR PULLEY WITH CLUTCH

a.

When rotating the pulley, check that it turns clockwise and that it does not turn counterclockwise.

If the result is not as specified, replace the generator pulley with clutch.