Home › Power Source / Network › 2TR-FBE BATTERY / CHARGING › GENERATOR
RM1840EF _57 Power Source / Network _009637 2TR-FBE BATTERY / CHARGING _0052674 GENERATOR G

2TR-FBE BATTERY / CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 1.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

a.
A118443
1.145,0.443 1.321,0.606 0.176,0.163 10 *1 1.108,0.536 0.962,0.536 0.962,0.536 0.811,0.694 false
*1 Length


Using a vernier caliper, measure the brush length.

Standard length:

9.5 to 11.5 mm (0.374 to 0.453 in.)


Minimum length:

4.5 mm (0.177 in.)


If the brush length is less than the minimum, replace the generator brush holder assembly.


Hide 2.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A118444

Check that the bearing is not rough or worn, and that it rotates smoothly.

If necessary, replace the generator rotor assembly.


b.

Check the generator rotor for an open circuit.

i.
A236749
2.219,0.865 2.552,0.229 2.552,0.229 2.698,0.229 true 2.708,0.135 2.885,0.313 0.177,0.177 10 false *1
*1 Slip Ring


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.85 to 2.25 Ω


If the result is not as specified, replace the generator rotor assembly.



c.

Check if the generator rotor is grounded.

i.
A236750
2.354,0.917 2.479,0.427 2.479,0.427 2.563,0.427 false 1.208,0.417 0.958,0.167 0.958,0.167 0.885,0.167 true 2.573,0.344 2.76,0.521 0.188,0.177 10 false *2 0.719,0.104 0.896,0.25 0.177,0.146 10 false *1
*1 Rotor Core
*2 Slip Ring


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor Core Always 10 kΩ or higher


If the result is not as specified, replace the generator rotor assembly.



d.

Check each slip ring.

i.

Check that the slip rings are not rough or scored.

If rough or scored, replace the generator rotor assembly.


ii.
A118447

Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.8 mm (0.559 to 0.583 in.)


Minimum diameter:

14.0 mm (0.551 in.)