1.INSPECT NO. 1 COOLER WIRE
Measure the resistance according to the value(s) in the table below.
| *a | Terminal A | *b | Terminal B |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A1 - B1 | Always | Below 1 Ω |
| A2 - B2 | Always | Below 1 Ω |
| A3 - B3 | Always | Below 1 Ω |
| A4 - B4 | Always | Below 1 Ω |
| A5 - B5 | Always | Below 1 Ω |
| A6 - B6 | Always | Below 1 Ω |
| A7 - B7 | Always | Below 1 Ω |
| A8 - B8 | Always | Below 1 Ω |
| A9 - B9 | Always | Below 1 Ω |
| A10 - B10 | Always | Below 1 Ω |
| A11 - B11 | Always | Below 1 Ω |
| A12 - B12 | Always | Below 1 Ω |
| A13 - B13 | Always | Below 1 Ω |
| A14 - B14 | Always | Below 1 Ω |
| A15 - B15 | Always | Below 1 Ω |
If the result is not as specified, replace the No. 1 cooler wire.