Home › Vehicle Interior › HEATING / AIR CONDITIONING › SOLAR SENSOR(for Automatic Air Conditioning System)
RM1840EF _58 Vehicle Interior _009648 HEATING / AIR CONDITIONING _0052759 SOLAR SENSOR(for Automatic Air Conditioning System) G

HEATING / AIR CONDITIONING  SOLAR SENSOR(for Automatic Air Conditioning System)  INSPECTION  


PROCEDURE

Hide 1.INSPECT COOLER THERMISTOR (SOLAR SENSOR)

E225715
1.573,1.406 1.104,1.875 true 1.917,1.417 2.354,1.896 true 0.094,0.052 0.281,0.229 0.188,0.177 10 false *a 1.854,1.24 1.958,1.417 0.104,0.177 10 false 1 1.531,1.24 1.646,1.417 0.115,0.177 10 false 2 0.792,1.813 1.094,2 0.302,0.188 10 false SS- 2.417,1.813 2.719,2 0.302,0.188 10 false SS+
*a Component with harness connected
(Cooler Thermistor (Solar Sensor))


a.

Connect the connector.


b.

Turn the ignition switch to ON.


c.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
1 (SS+) - 2 (SS-) Sensor not exposed to sunlight or inspection light Below 0.8 V
Sensor exposed to sunlight or inspection light 0.8 to 4.3 V


If the resistance is not as specified, replace the cooler thermistor (solar sensor).

HINT:
·

Check from the rear of the connector while it is connected to the cooler thermistor (solar sensor).

·

Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).