The thermistor assembly connected to the accessory meter detects fluctuations in the ambient temperature. This information is used for controlling the interior temperature. The accessory meter detects the resistance of the thermistor assembly and sends this information to the air conditioning amplifier assembly.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Memory | Note |
|---|---|---|---|---|---|
| 12 | Ambient Temperature Sensor Circuit | An open or short in ambient temperature sensor circuit | ·
Thermistor assembly ·
Accessory meter assembly ·
Air conditioning amplifier assembly ·
Harness or connector |
- | - |
Check that the accessory meter assembly illuminates normally before performing the following inspection procedure.
Check the difference between the ambient temperature value displayed on the accessory meter assembly and the actual ambient temperature.
The ambient temperature displayed on the accessory meter assembly and the actual ambient temperature are almost the same.
The temperature displayed on the accessory meter assembly and the actual temperature detected by the thermistor assembly may differ when the ambient temperature changes significantly (for example, when the vehicle is entering/exiting tunnels, or the vehicle speed or wind direction changes).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G32 accessory meter assembly connector.
Disconnect the G94 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G32-9 (DATA) - G94-18 (TAMO) | Always | Below 1 Ω |
| G32-9 (DATA) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK (When troubleshooting according to problem symptoms table.) | A |
| OK (When troubleshooting according to DTC.) | B |
| NG | C |
A
B
C
| *a | Resistance (kΩ) |
| *b | Temperature |
Remove the thermistor assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 10°C (50°F) | 3.00 to 3.73 kΩ |
| 15°C (59°F) | 2.45 to 2.88 kΩ | |
| 20°C (68°F) | 1.95 to 2.30 kΩ | |
| 25°C (77°F) | 1.60 to 1.80 kΩ | |
| 30°C (86°F) | 1.28 to 1.47 kΩ | |
| 35°C (95°F) | 1.00 to 1.22 kΩ | |
| 40°C (104°F) | 0.80 to 1.00 kΩ | |
| 45°C (113°F) | 0.65 to 0.85 kΩ | |
| 50°C (122°F) | 0.50 to 0.70 kΩ | |
| 55°C (131°F) | 0.44 to 0.60 kΩ | |
| 60°C (140°F) | 0.36 to 0.50 kΩ |
Even slightly touching the thermistor assembly may change the resistance value. Be sure to hold the connector of the thermistor assembly.
When measuring the resistance, the thermistor assembly temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (Refer to the graph).
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the G32 accessory meter assembly connector.
Disconnect the A22 thermistor assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G32-3 (TH+) - A22-2 | Always | Below 1 Ω |
| G32-2 (SG) - A22-1 | ||
| G32-3 (TH+) - Body ground | Always | 10 kΩ or higher |
| G32-2 (SG) - Body ground |
| Proceed to |
|---|
| OK |
| NG |
OK
NG