The No. 1 heater relay is turned on by signals from the air conditioning amplifier assembly. The No. 1 heater relay supplies power to the blower motor control.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Remove the No. 1 heater relay from the driver side junction block assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>RELAY(for Heater)>REMOVAL
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 4 | Battery voltage is not applied to terminals 1 and 2 | Below 1 Ω |
| 3 - 5 | 10 kΩ or higher | |
| 3 - 4 | Battery voltage is applied to terminals 1 and 2 | 10 kΩ or higher |
| 3 - 5 | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the No. 1 heater relay from the driver side junction block assembly.
Click hereVehicle Interior>HEATING / AIR CONDITIONING>RELAY(for Heater)>REMOVAL
Disconnect the G94 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| No. 1 heater relay terminal 2 - G94-14 (HR) | Always | Below 1 Ω |
| No. 1 heater relay terminal 2 - Body ground | Always | 10 kΩ or higher |
| No. 1 heater relay terminal 3 - Body ground | Always | 10 kΩ or higher |
| No. 1 heater relay terminal 4 - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| No. 1 heater relay terminal 1 - Body ground | Ignition switch ON | 11 to 14 V |
| Ignition switch off | Below 1 V | |
| No. 1 heater relay terminal 5 - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Component with harness connected
(Air Conditioning Amplifier Assembly) |
Remove the air conditioning amplifier assembly with its connectors still connected.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| G94-14 (HR) - Body ground | ·
Ignition switch off ·
Blower switch off |
Below 1 V |
·
Ignition switch ON ·
Blower switch on (LO level) |
Below 1 V | |
·
Ignition switch ON ·
Blower switch off |
11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG