Home › Vehicle Exterior › LIGHTING (EXT) › HAZARD WARNING SWITCH
RM1840EF _59 Vehicle Exterior _009655 LIGHTING (EXT) _0052823 HAZARD WARNING SWITCH G

LIGHTING (EXT)  HAZARD WARNING SWITCH  INSPECTION  


PROCEDURE

Hide 1.INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY (for Manual Cooler System)

a.
E155916
0.104,0.083 0.448,0.323 0.344,0.24 10 false *a
*a Component without harness connected (Hazard Warning Signal Switch Assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Switch Condition Specified Condition
2 - 4 Off 10 kΩ or higher
2 - 4 On Below 1 Ω

If the result is not as specified, there may be a malfunction in the hazard warning signal switch.


Hide 2.INSPECT INTEGRATION PANEL SUB-ASSEMBLY (for Automatic Cooler System)

a.
E226171
0.948,1.271 1.25,1.229 true 2.167,1.104 2.51,1.042 true 0.125,0.073 0.469,0.396 0.344,0.323 10 false *a 0.625,1.198 1.021,1.51 0.396,0.313 10 false SW1 2.552,0.969 2.99,1.25 0.438,0.281 10 false GND
*a Component without harness connected (Integration Panel Sub-assembly)


Measure the resistance according to the value(s) in the table below.

Standard Resistance
Tester Connection Switch Condition Specified Condition
1 (GND) - 16 (SW1) Hazard warning signal switch Off 10 kΩ or higher
1 (GND) - 16 (SW1) Hazard warning signal switch On Below 1 Ω

If the result is not as specified, there may be a malfunction in the integration panel sub-assembly.