This circuit is the power source circuit for the meter.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
| *a | Front view of wire harness connector
(to Combination Meter Assembly) |
Disconnect the G19 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G19-22 (EP) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G19-1 (B) - Body ground | Always | 11 to 14 V |
| G19-21 (IG+) - Body ground | Ignition switch ON | 11 to 14 V |
| G19-21 (IG+) - Body ground | Ignition switch off | Below 1 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG