The combination meter receives vehicle speed signals from the speedometer sensor via the direct line.
| *a | Component with harness connected
(Combination Meter Assembly) |
Remove the combination meter assembly with the connector(s) still connected.
Using an oscilloscope, check the signal waveform of the meter.
| Item | Content |
|---|---|
| Tester Connection | G19-5 (SI) - Body ground |
| Tool Setting | 5 V/DIV., 20 msec./DIV. |
| Condition | Driving at approximately 20 km/h (12 mph) |
As the vehicle speed increases, the wavelength shortens.
The waveform displayed is as shown in the illustration.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the transmission type.
| Result | Proceed to |
|---|---|
| for Automatic Transmission | A |
| for Manual Transmission | B |
A
B
Disconnect the C38 speedometer sensor connector.
Disconnect the G19 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G19-5 (SI) - C38-3 (SI) | Always | Below 1 Ω |
| G19-31 (MS5) - C38-1 (IG+) | Always | Below 1 Ω |
| C38-1 (IG+) - C38-2 (SE) | Always | 10 kΩ or higher |
| C38-1 (IG+) - C38-3 (SI) | Always | 10 kΩ or higher |
| C38-2 (SE) - C38-3 (SI) | Always | 10 kΩ or higher |
| C38-2 (SE) - Body ground | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for 340F) | B |
| OK (for 343E) | C |
| OK (for 343F) | D |
| OK (for 750F) | E |
A
B
C
D
E
Disconnect the C38 speedometer sensor connector.
Disconnect the G19 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| G19-5 (SI) - C38-3 (SI) | Always | Below 1 Ω |
| G19-31 (MS5) - C38-1 (IG+) | Always | Below 1 Ω |
| C38-1 (IG+) - C38-2 (SE) | Always | 10 kΩ or higher |
| C38-1 (IG+) - C38-3 (SI) | Always | 10 kΩ or higher |
| C38-2 (SE) - C38-3 (SI) | Always | 10 kΩ or higher |
| C38-2 (SE) - Body ground | Always | Below 1 Ω |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (for VF2A) | B |
| OK (for R150F, R151F, R156F) | C |
| OK (for R150, R151, R156) | D |
A
B
C
D