Home › General › SPECIFICATIONS › 2TR-FE STARTING › from 2013.10
RM1840EF _V1 General _009566 SPECIFICATIONS _0051966 2TR-FE STARTING F

SPECIFICATIONS  2TR-FE STARTING  SERVICE DATA  


Starter (1.6 kW Type):
Starter assembly No-load characteristics current Standard current 90 A or less at 11.5 V
Starter armature assembly Segment - Segment Standard resistance Below 1 Ω
Segment - Armature coil core Standard resistance 10 kΩ or higher
Commutator diameter Standard 29.0 mm (1.14 in.)
Minimum 28.0 mm (1.10 in.)
Commutator circle runout Maximum 0.05 mm (0.00197 in.)
Commutator undercut depth Standard 0.7 mm (0.0276 in.)
Minimum 0.2 mm (0.00787 in.)
Starter brush holder assembly Brush length Standard 14.4 mm (0.567 in.)
Minimum 9.0 mm (0.354 in.)
Brush spring load Standard 16 to 20 N (1.7 to 2.0 kgf, 3.6 to 4.5 lbf)
Minimum 6.7 N (0.7 kgf, 1.5 lbf)
Positive brush holder - Negative brush holder Standard resistance 10 kΩ or higher
Magnet starter switch assembly Terminal 50 - Terminal C Standard resistance Below 1 Ω
Terminal 50 - Body Standard resistance Below 2 Ω

Starter (1.7 kW Type):
Starter assembly No-load characteristics current Standard current 90 A or less at 10.9 V
Starter armature assembly Segment - Segment Standard resistance 3.0 to 3.3 Ω
Segment - Coil core Standard resistance 10 kΩ or higher
Commutator circle runout Standard 0.02 mm (0.000787 in.)
Maximum 0.04 mm (0.00157 in.)
Commutator diameter Standard 32.2 mm (1.27 in.)
Minimum 31.1 mm (1.22 in.)
Commutator undercut depth Standard 0.9 mm (0.0354 in.)
Minimum 0.4 mm (0.0157 in.)
Starter brush holder assembly Brush length Standard 11.3 mm (0.445 in.)
Minimum 7.5 mm (0.295 in.)
Magnet starter switch assembly Terminal 50 - Terminal C Standard resistance Below 1 Ω
Terminal 50 - Body Standard resistance Below 2 Ω