Home › Vehicle Exterior › MIRROR (EXT) › OUTER MIRROR SWITCH › from 2014.04
RM1840EF _59 Vehicle Exterior _009653 MIRROR (EXT) _0052807 OUTER MIRROR SWITCH G

MIRROR (EXT)  OUTER MIRROR SWITCH  INSPECTION  


PROCEDURE

Hide 1.INSPECT NO. 2 OUTER MIRROR SWITCH ASSEMBLY

a.
B207176
1.354,3.708 0.917,4.115 true 1.646,3.708 1.531,4.115 true 1.885,3.708 2.198,4.115 true 1.51,3.698 1.188,4.094 true 2.01,3.698 2.604,4.135 true 2.135,3.698 3.021,4.073 true 2.104,0.792 2.104,0.281 2.104,0.281 2.25,0.281 true 1.26,3.615 0.875,3.146 true 1.76,3.719 1.76,4.115 true 1.104,3.625 0.729,3.625 true 1.583,0.792 1.583,0.281 1.583,0.281 1.375,0.281 true 1.167,0.177 1.427,0.417 0.26,0.24 10 false *1 0.813,4.125 1.042,4.313 0.229,0.188 10 false B 1.375,4.125 1.688,4.333 0.313,0.208 10 false M+ 1.104,4.125 1.323,4.323 0.219,0.198 10 false E 1.667,4.135 2.042,4.406 0.375,0.271 10 false MLH 2.063,4.146 2.51,4.323 0.448,0.177 10 false MLV 2.469,4.146 2.938,4.365 0.469,0.219 10 false MRV 2.927,4.135 3.375,4.344 0.448,0.208 10 false MRH 0.469,3.531 0.781,3.729 0.313,0.198 10 false MF 0.583,3.042 0.906,3.219 0.323,0.177 10 false MR 2.302,0.167 2.49,0.375 0.188,0.208 10 false *2 0.167,2.25 0.354,2.458 0.188,0.208 10 false *a
*1 Select Switch
*2 Retract Switch
*a Component without harness connected
(No. 2 Outer Mirror Switch Assembly)


w/ Retract Mirror:

Inspect the No. 2 outer mirror switch assembly.

i.

Select "L" on the select switch.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
4 (MLV) - 8 (B)
6 (M+) - 7 (E)
UP Pressed Below 1 Ω
Not pressed 10 kΩ or higher
4 (MLV) - 7 (E)
6 (M+) - 8 (B)
DOWN Pressed Below 1 Ω
Not pressed 10 kΩ or higher
5 (MLH) - 8 (B)
6 (M+) - 7 (E)
LEFT Pressed Below 1 Ω
Not pressed 10 kΩ or higher
5 (MLH) - 7 (E)
6 (M+) - 8 (B)
RIGHT Pressed Below 1 Ω
Not pressed 10 kΩ or higher


If the result is not as specified, replace the No. 2 outer mirror switch assembly.


iii.

Select "R" on the select switch.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
3 (MRV) - 8 (B)
6 (M+) - 7 (E)
UP Pressed Below 1 Ω
Not pressed 10 kΩ or higher
3 (MRV) - 7 (E)
6 (M+) - 8 (B)
DOWN Pressed Below 1 Ω
Not pressed 10 kΩ or higher
2 (MRH) - 8 (B)
6 (M+) - 7 (E)
LEFT Pressed Below 1 Ω
Not pressed 10 kΩ or higher
2 (MRH) - 7 (E)
6 (M+) - 8 (B)
RIGHT Pressed Below 1 Ω
Not pressed 10 kΩ or higher


If the result is not as specified, replace the No. 2 outer mirror switch assembly.


v.

Inspect the retract switch.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
7 (E) - 10 (MF)
8 (B) - 9 (MR)
Pushed in Below 1 Ω
7 (E) - 9 (MR)
8 (B) - 10 (MF)
Not pushed in Below 1 Ω


If the result is not as specified, replace the No. 2 outer mirror switch assembly.



b.
B203252
1.385,3.677 0.813,4.083 false 1.604,3.698 1.396,4.094 false 1.74,3.708 1.781,4.104 false 1.885,3.688 2.25,4.094 false 1.479,3.698 1.083,4.094 false 2.01,3.688 2.646,4.094 false 2.115,3.688 3.167,4.083 false 2.104,0.917 2.563,0.917 false 0.24,2.219 0.531,2.385 0.292,0.167 10 false *a 2.573,0.823 2.823,1 0.25,0.177 10 false *1 0.729,4.104 0.938,4.25 0.208,0.146 10 false B 1.26,4.104 1.542,4.26 0.281,0.156 10 false M+ 1,4.104 1.219,4.25 0.219,0.146 10 false E 1.573,4.104 1.969,4.281 0.396,0.177 10 false MLH 2.063,4.104 2.479,4.26 0.417,0.156 10 false MLV 2.49,4.104 2.896,4.292 0.406,0.188 10 false MRV 3,4.104 3.406,4.271 0.406,0.167 10 false MRH
*1 Select Switch
*a Component without harness connected
(No. 2 Outer Mirror Switch Assembly)


w/o Retract Mirror:

Inspect the No. 2 outer mirror switch assembly.

i.

Select "L" on the select switch.


ii.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
4 (MLV) - 8 (B)
6 (M+) - 7 (E)
UP Pressed Below 1 Ω
Not pressed 10 kΩ or higher
4 (MLV) - 7 (E)
6 (M+) - 8 (B)
DOWN Pressed Below 1 Ω
Not pressed 10 kΩ or higher
5 (MLH) - 8 (B)
6 (M+) - 7 (E)
LEFT Pressed Below 1 Ω
Not pressed 10 kΩ or higher
5 (MLH) - 7 (E)
6 (M+) - 8 (B)
RIGHT Pressed Below 1 Ω
Not pressed 10 kΩ or higher


If the result is not as specified, replace the No. 2 outer mirror switch assembly.


iii.

Select "R" on the select switch.


iv.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Switch Condition Specified Condition
3 (MRV) - 8 (B)
6 (M+) - 7 (E)
UP Pressed Below 1 Ω
Not pressed 10 kΩ or higher
3 (MRV) - 7 (E)
6 (M+) - 8 (B)
DOWN Pressed Below 1 Ω
Not pressed 10 kΩ or higher
2 (MRH) - 8 (B)
6 (M+) - 7 (E)
LEFT Pressed Below 1 Ω
Not pressed 10 kΩ or higher
2 (MRH) - 7 (E)
6 (M+) - 8 (B)
RIGHT Pressed Below 1 Ω
Not pressed 10 kΩ or higher


If the result is not as specified, replace the No. 2 outer mirror switch assembly.