AIR CONDITIONING SYSTEM > GENERAL |
| OUTLINE |
A manual air conditioning system and automatic air conditioning system are used.
A rear cooler system is used.
The automatic air conditioning is provided with a partial recirculation system, which improves heating performance.
| SPECIFICATION |
Performance
| Model | Front | Rear | |
| Heater | Heater Output | 5000 W | - |
| Air Flow Volume | 320 m3/h | - | |
| Power Consumption | 190 W | - | |
| Quick Heater Assembly (PTC Heater)* | Heater Output | 450 W | - |
| Cooler | Cooling Capacity | 4600 W | 2830 W |
| Air Flow Volume | 470 m3/h | 260 m3/h | |
| Power Consumption | 230 W | 180 W | |
| Model | Front | Rear | |
| Heater | Heater Output | 5000 W | - |
| Air Flow Volume | 320 m3/h | - | |
| Power Consumption | 190 W | - | |
| Cooler | Cooling Capacity | 4600 W | 2830 W |
| Air Flow Volume | 470 m3/h | 260 m3/h | |
| Power Consumption | 230 W | 180 W | |
| Model | Front | Rear | |
| Heater | Heater Output | 5000 W | - |
| Air Flow Volume | 320 m3/h | - | |
| Power Consumption | 190 W | - | |
| Cooler | Cooling Capacity | 4600 W | 2830 W |
| Air Flow Volume | 470 m3/h | 260 m3/h | |
| Power Consumption | 230 W | 180 W | |
| Model | Front | Rear | |
| Heater | Heater Output | 5000 W | - |
| Air Flow Volume | 320 m3/h | - | |
| Power Consumption | 190 W | - | |
| Cooler | Cooling Capacity | 4600 W | 2830 W |
| Air Flow Volume | 470 m3/h | 260 m3/h | |
| Power Consumption | 230 W | 180 W | |
Ventilation and Heater Radiator
| Model | Front | Rear | |
| Heater Radiator Unit Sub-assembly | Type | Straight Flow Aluminum-II (SFA-II) | - |
| Size W x H x L | 201.5 mm x 150 mm x 21 mm (7.9 in. x 5.9 in. x 0.8 in.) | - | |
| Fin Pitch | 1.8 mm (0.07 in.) | - | |
| Blower with Fan Motor Sub-assembly | Motor Type | K70-10.5T | K62F-13.5 W |
| Fan Type | Semi Shroud Fan | ||
| Fan Size Dia. x H | 155 mm x 65 mm (6.1 in. x 2.6 in.) | 155 mm x 75 mm (6.1 in. x 2.9 in.) | |
Air Conditioning
| Model | Front | Rear | |
| Cooler Condenser Assembly | Type | Multi-Flow-III (MF-III) Sub-cool*1, *2 Multi-Flow-IV (MF-IV) Sub-cool*3, *4 | |
| Size W x H x L | 570 mm x 520.8 mm x 16 mm*1, *2 (22.4 in. x 20.5 in. x 0.6 in.) 620 mm x 530.2 mm x 16 mm*3, *4 (24.4 in. x 20.87 in. x 0.6 in.) | ||
| Fin Pitch | 3.6 mm (0.14 in.)*1, *2 3.55 mm (0.13 in.)*3, *4 | ||
| No. 1 Cooler Evaporator Sub-assembly | Type | Revolutionary Super-slim Structure (RS) | |
| Size W x H x L | 226.1 mm x 241 mm x 38 mm (8.9 in. x 9.5 in. x 1.5 in.) | 118.9 mm x 251 mm x 38 mm (4.68 in. x 9.88 in. x 1.5 in.) | |
| Fin Pitch | 3.0 mm (0.11 in.) | ||
| Cooler Compressor Assembly | Type | 10S15 | |
| Pulley | Magnetic Clutch | ||
| Refrigerant | Type | R134a | |
| Charge Volume | 750 g | ||
| MAIN FEATURES |
The air conditioning system has the following features:
| Item | Feature |
| Manual and Automatic Common | The following parts are used to ensure high cooling performance while achieving a compact and lightweight construction:
|
| Automatic | Defroster control logic is used to improve defroster performance. |