Home › ENGINE · 2TR-FE › STARTING › STARTER (for 1.7 kW Type)

STARTER (for 1.7 kW Type) > INSPECTION

for Preparation Click here



1. INSPECT STARTER ASSEMBLY


A122416E01

NOTICE:
These tests must be performed within 3 to 5 seconds to prevent the coil from burning out.



  1. Perform pull-in/holding test.

    1. Disconnect the lead wire from terminal C.

    2. Connect the battery to the magnetic switch as shown in the illustration. Then check that the clutch pinion gear moves outward.



    3. A122417E01
    4. With the battery connected as above with the clutch pinion gear out, disconnect the negative (-) lead from terminal C. Check that the pinion gear remains out.



    5. A122418E01
    6. Disconnect the negative (-) lead from the starter body. Check that the clutch pinion gear returns inward.
      If the result is not as specified, replace the starter assembly.



    A122419E01
  1. Perform operation test without load.

    1. Connect the lead wire to terminal C.

      Torque:
      8.0 N*m{ 82 kgf*cm , 71 in.*lbf }

    2. Mount the starter with a vise.

    3. Connect the battery and ammeter to the starter as shown in the illustration.

    4. Check that the starter rotates smoothly and steadily while the pinion gear is moving out. Then measure the current.

      Standard current:
      90 A or less at 10.9 V

      If the result is not as specified, replace the starter assembly.



2. INSPECT STARTER ARMATURE ASSEMBLY


    A122024
  1. Check the commutator for open circuit.

    1. Measure the resistance between the segments of the commutator.

      Standard resistance:
      2.7 to 3.3 Ω

      If the result is not as specified, replace the armature assembly.



    A122025
  1. Check the commutator for ground.

    1. Measure the resistance between the commutator and armature core.

      Standard resistance:
      10 kΩ higher

      If the result is not as specified, replace the armature assembly.

  1. Check the commutator for dirt and / or burns on the surface.
    If the surface is dirty or burnt, correct it with sandpaper (No. 400) or a lathe.



    A122026
  1. Check for the commutator circuit runout.

    1. Place the commutator on V-blocks.

    2. Using a dial indicator, measure the circle runout.

      Standard runout:
      0.02 mm (0.0008 in.)

      Maximum runout:
      0.04 mm (0.0016 in.)

      If the runout is greater than the maximum, replace the armature assembly.



    A122027
  1. Using a vernier caliper, measure the commutator diameter.

    Standard diameter:
    32.2 mm (1.2677 in.)

    Minimum diameter:
    31.1 mm (1.2244 in.)

    If the diameter is less than the minimum, replace the armature assembly.



    A122028
  1. Using a vernier caliper, measure the undercut depth of the commutator.

    Standard depth:
    0.9 mm (0.0354 in.)

    Minimum depth:
    0.4 mm (0.0157 in.)

    If the undercut depth is less than the minimum, replace the armature assembly.



3. INSPECT STARTER BRUSH HOLDER ASSEMBLY


    A122029
  1. Using a vernier caliper, measure the brush length.

    Standard length:
    11.3 mm (0.4449 in.)

    Minimum length:
    7.5 mm (0.2953 in.)

    If the length is less than the minimum, replace the brush holder assembly.



    A122030E01
  1. Check the brush holder.

    1. Using an ohmmeter, measure the resistance between the brushes.

      Standard resistance:
      Tester Connection
      Specified Condition
      A - B
      10 kΩ or higher
      A - C
      10 kΩ or higher
      A - D
      Below 1 Ω
      B - C
      Below 1 Ω
      B - D
      10 kΩ or higher
      C - D
      10 kΩ or higher

      If the standard is not met, replace the brush holder assembly.



4. INSPECT STARTER CLUTCH SUB-ASSEMBLY


    A122031E01
  1. Check the starter clutch pinion gear.

    1. Hold the starter clutch and rotate the pinion gear clockwise, and check that it turns freely. Try to rotate the pinion gear counterclockwise and check that it locks.
      If necessary, replace the starter clutch sub-assembly.



5. INSPECT MAGNET STARTER SWITCH ASSEMBLY


    A122032E01
  1. Check the plunger.

    1. Install the plunger and spring onto the switch body.



    A122033
  1. Push in the plunger and check that it returns quickly to its original position.
    If necessary, replace the magnet starter switch assembly.



    A122034E01
  1. Check the pull-in coil for open circuit.

    1. Using an ohmmeter, check that there is continuity between terminal 50 and C.
      If there is no continuity, replace the magnet starter switch assembly.



    A122035E01
  1. Check whether the holding coil has an open circuit.

    1. Using an ohmmeter, check that there is continuity between terminal 50 and the switch body.
      If there is no continuity, replace the magnet starter switch assembly.