DTC P0102 Mass or Volume Air Flow Circuit Low Input |
DTC P0103 Mass or Volume Air Flow Circuit High Input |

| DTC No. | DTC Detection Condition | Trouble Area |
| P0102 | The mass air flow meter voltage is below 0.2 V for 3 seconds (1-trip detection logic). |
|
| P0103 | The mass air flow meter voltage is higher than 4.9 V for 3 seconds (1-trip detection logic). |
|
| Mass Air Flow Rate (g/ms) | Malfunction |
| Approximately 0.0 |
|
| 160.0 or more |
|

| 1.READ DTC OUTPUT |
Connect the intelligent tester to the DLC3.
Turn the ignition switch ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Read the values displayed on the tester.
| Result | Proceed to |
| DTC P0102 is output | A |
| DTC P0103 is output | B |
|
| ||||
| A | |
| 2.INSPECT MASS AIR FLOW METER (POWER SOURCE VOLTAGE) |
![]() |
Disconnect the mass air flow meter connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A4-1 (+B) - Body ground | Ignition switch ON | 11 to 14 V |
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
Reconnect the mass air flow meter connector.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A4-3 (VG) - E20-13 (VG) | Always | Below 1 Ω |
| A4-2 (E2G) - E20-7 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A4-3 (VG) or E20-13 (VG) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | |
| 4.CHECK MASS AIR FLOW METER |
Inspect the mass air flow meter, referring to the On-vehicle Inspection for Mass Air Flow Meter (Click here).
Inspect the mass air flow meter, referring to the Inspection for Mass Air Flow Meter (Click here).
Inspect the function of the mass air flow meter.
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Powertrain / Engine and ECT / Data List / MAF.
Start the engine.
Check that the MAF value changes when the engine is raced.
|
| ||||
| OK | ||
| ||
| 5.CHECK HARNESS AND CONNECTOR (SENSOR GROUND) |
![]() |
Disconnect the mass air flow meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A4-2 (E2G) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Mass Air Flow Meter) |
Reconnect the mass air flow meter connector.
|
| ||||
| OK | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the mass air flow meter connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A4-2 (E2G) - E20-7 (E2G) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A4-2 (E2G) or E20-7 (E2G) - Body ground | Always | 10 kΩ or higher |
Reconnect the mass air flow meter connector.
Reconnect the ECM connector.
|
| ||||
| OK | ||
| ||
| 7.CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY [MAIN RELAY]) |
Disconnect the mass air flow meter connector.
Remove the integration relay (MAIN relay) from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A4-1 (+B) - 1J-5 | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
| A4-1 (+B) or 1J-5 - Body ground | Always | 10 kΩ or higher |
Reinstall the integration relay.
Reconnect the mass air flow meter connector.
|
| ||||
| OK | ||
| ||