Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › REFRIGERANT

REFRIGERANT > REPLACEMENT

for Preparation Click here



1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
  1. Start the engine.

  1. Operate the cooler compressor under the conditions shown below:
    Item
    Condition
    Engine Speed
    Idling
    Operating Time
    3 minutes or more
    A/C Switch Status
    On
    Blower Switch Status
    HI
    Set Temperature
    MAX COOL
    This causes most of the compressor oil from the various components of the A/C system to collect in the A/C compressor.

    NOTICE:
    It is not necessary to operate the cooler compressor if the A/C does not operate because of compressor lock, etc.

  1. Stop the engine.

  1. Recover the refrigerant from the A/C system using a refrigerant recovery unit.

    HINT:
    Use the refrigerant recovery unit in accordance with the manufacturer's instruction manual.



2. CHARGE REFRIGERANT
SST
09985-20010   (09985-02130, 09985-02150, 09985-02090, 09985-02110, 09985-02010, 09985-02050, 09985-02060, 09985-02070)
  1. Perform vacuum purging using a vacuum pump.



  1. Charge refrigerant HFC-134a (R134a).

    Standard:
    750 +-30 g (26.45 +-1.05 oz.)



    I037365E02

    NOTICE:
    1. Do not operate the cooler compressor before charging refrigerant as the cooler compressor will not work properly without any refrigerant, and will overheat.
    1. Approximately 100 g (3.53 oz.) of refrigerant may need to be charged after bubbles disappear. The refrigerant amount should be checked by quantity, and not with the sight glass.



3. WARM UP ENGINE
  1. Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.

    NOTICE:
    Be sure to warm up the compressor when turning the A/C switch ON after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.



4. CHECK FOR LEAKAGE OF REFRIGERANT
  1. After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.

  1. Perform the operation under these conditions:

    1. Stop the engine.
    1. Secure good ventilation (the gas leak detector may react to volatile gases other than refrigerant, such as evaporated gasoline or exhaust gas).
    1. Repeat the test 2 or 3 times.
    1. Make sure that some refrigerant remains in the refrigeration system. When compressor is off: approximately 392 to 588 kPa (4 to 6 kgf/cm2, 57 to 85 psi)



    I042222E02
  1. Using a gas leak detector, check the refrigerant line for leakage.

  1. If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.

  1. Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.