Home › ENGINE ยท 1GR-FE › ENGINE CONTROL SYSTEM › VVT SENSOR

VVT SENSOR > REMOVAL

for Preparation Click here



1. REMOVE PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).



2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL


3. DRAIN ENGINE COOLANT
  1. Remove the radiator cap.



  1. Loosen the cylinder block drain cock plug and radiator drain cock plug, and then drain the coolant.

    HINT:
    Collect the coolant in a container and dispose of it according to the regulations in your area.



    A270641E01



4. REMOVE V-BANK COVER


    A112983
  1. Remove the 2 nuts and V-bank cover.



5. REMOVE NO. 2 VENTILATION HOSE


A075594


6. REMOVE AIR CLEANER ASSEMBLY


    A075595
  1. Disconnect the vacuum hose.

  1. Disconnect the MAF meter connector.

  1. Remove the 2 wire harness clamps.



    A075596
  1. Loosen the 2 hose clamps.

  1. Remove the 2 bolts and air cleaner.



7. REMOVE VVT SENSOR (for Bank 1)


    G038105
  1. Disconnect the sensor connector.

  1. Remove the bolt and sensor.



8. REMOVE VVT SENSOR (for Bank 2)


    A076414
  1. Disconnect the No. 4 and No. 5 water by-pass hoses.

  1. Disconnect the sensor connector.



    G038106
  1. Remove the bolt and sensor.