Home › BODY ELECTRICAL › METER › METER / GAUGE SYSTEM

METER / GAUGE SYSTEM > Fuel Gauge Malfunction

for Preparation Click here


WIRING DIAGRAM


E236128E01


INSPECTION PROCEDURE

1.CHECK FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY (FUEL SENDER GAUGE)
E134967E04
  1. Disconnect the F14*1 or F13*2 pump and gauge connector.

    1. *1: for 1GR-FE, 2TR-FE, 2TR-FBE
    2. *2: for 1KD-FTV

  1. Turn the ignition switch ON, and then check the position of the receiver gauge needle.

    OK:
    Fuel receiver gauge indicates E.

  1. Connect terminals 2 and 3 on the wire harness side connector.

  1. Turn the ignition switch ON, and then check the position of the receiver gauge needle.

    OK:
    Fuel receiver gauge indicates F.



NG
Go to step 3
OK


2.INSPECT FUEL SENDER GAGE ASSEMBLY
E224605E05
A237764E05
  1. except 2TR-FBE:

    1. Remove the fuel sender gauge assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      Float position F (upper)
      3 to 5 Ω
      Float position E (lower)
      109 to 111 Ω

  1. for 2TR-FBE:

    1. Remove the fuel sender gauge assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      Float position F (upper)
      13.5 to 16.5 Ω
      Float position E (lower)
      401.8 to 418.2 Ω



NG
REPLACE FUEL SENDER GAGE ASSEMBLY
OK

REPLACE FUEL SUCTION WITH PUMP AND GAUGE TUBE ASSEMBLY 

3.CHECK WIRE HARNESS (METER - GAUGE)

E215352E03

  1. Disconnect the C26 meter connector.

  1. Disconnect the F14*1 or F13*2 pump and gauge connector.

    1. *1: for 1GR-FE, 2TR-FE, 2TR-FBE
    2. *2: for 1KD-FTV

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for 1GR-FE, 2TR-FE, 2TR-FBE 
    Tester Connection
    Specified Condition
    C26-2 - F14-3
    Below 1 Ω
    C26-3 - F14-2
    Below 1 Ω

    for 1KD-FTV:
    Tester Connection
    Specified Condition
    C26-2 - F13-3
    Below 1 Ω
    C26-3 - F13-2
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE COMBINATION METER ASSEMBLY