Home › HEATER & AIR CONDITIONING SYSTEM › AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Manual Air Conditioning System)

AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) > TERMINALS OF ECU

for Preparation Click here



CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/o PTC HEATER)

I100991E04

  1. Disconnect the A14 amplifier connector.

  2. Measure the voltage and resistance of the wire harness side connector.

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    IG+ (A14-10) - GND (A14-18)
    R-L - L
    Power source (IG)
    Ignition switch OFF
    Below 1 V
    IG+ (A14-10) - GND (A14-18)
    R-L - L
    Power source (IG)
    Ignition switch ON
    10 to 14 V
    GND (A14-18) - Body ground
    L - Body ground
    Ground
    Always
    Below 1 Ω
    ACON (A14-4) - GND (A14-18)
    R-G - L
    A/C switch signal
    Ignition switch START
    Blower switch ON
    A/C switch OFF
    Below 1 V
    ACON (A14-4) - GND (A14-18)
    R-G - L
    A/C switch signal
    Ignition switch START
    Blower switch ON
    A/C switch ON
    10 to 14 V
    IND- (A14-13) - GND (A14-18)
    R-L - L
    A/C indicator light signal
    Ignition switch START
    Blower switch ON
    A/C switch OFF
    Below 1 V
    IND- (A14-13) - GND (A14-18)
    R-L - L
    A/C indicator light signal
    Ignition switch START
    Blower switch ON
    A/C switch ON
    10 to 14 V

    1. If the result is not as specified, there may be a malfunction on the wire harness side.

  3. Reconnect the A14 amplifier connector.

  4. Measure the voltage and resistance of the connector.

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    PSW (A14-3) - GND (A14-18)
    Y-B - L
    A/C pressure switch signal
    Ignition switch START
    Refrigerant pressure normal: 0.18 MPa (1.9 kgf/cm2, 26 psi) to 3.03 MPa (31.0 kgf/cm2, 440 psi)
    A/C switch ON
    Blower switch ON
    10 to 14 V
    PSW (A14-3) - GND (A14-18)
    Y-B - L
    A/C pressure switch signal
    Ignition switch START
    Refrigerant pressure less than 0.18 MPa (1.9 kgf/cm2, 26 psi) or more than 3.03 MPa (31.0 kgf/cm2, 440 psi)
    A/C switch ON
    Blower switch ON
    Below 1 V
    TE (A14-7) - SG-1 (A14-8)
    G - P
    A/C evaporator temperature sensor signal
    Ignition switch ON
    Evaporator temperature is 0°C (32°F)
    Temperature control knob: Max COOL
    2.0 to 2.4 V
    TE (A14-7) - SG-1 (A14-8)
    G - P
    A/C evaporator temperature sensor signal
    Ignition switch ON
    Evaporator temperature is 15°C (59°F)
    Temperature control knob: Max COOL
    1.4 to 1.8 V
    SG-1 (A14-8) - Body ground
    P - L
    Ground for A/C evaporator temperature sensor
    Always
    Below 1 Ω
    MGC (A14-1) - GND (A14-18)
    L-W - L
    Magnet clutch signal
    Ignition switch START
    Magnet clutch is not engaged
    Below 1 V
    MGC (A14-1) - GND (A14-18)
    L-W - L
    Magnet clutch signal
    Ignition switch START
    Magnet clutch is engaged
    10 to 14 V
    ACT (A14-2) - GND (A14-18)
    R-L - L
    Magnet on permit signal
    Ignition switch START
    A/C switch OFF
    Blower switch ON
    Below 1 V
    ACT (A14-2) - GND (A14-18)
    R-L - L
    Magnet on permit signal
    Ignition switch START
    A/C switch ON
    Blower switch ON
    10 to 14 V
    AC1 (A14-14) - GND (A14-18)
    Y - L
    Idle-up request signal
    Ignition switch START
    Magnet clutch is not engaged
    10 to 14 V
    AC1 (A14-14) - GND (A14-18)
    Y - L
    Idle-up request signal
    Ignition switch START
    Magnet clutch is engaged
    Below 1 V

    1. If the result is not as specified, the A/C amplifier may have a malfunction.


CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY (w/ PTC HEATER)

I100992E05

  1. Disconnect the A33 amplifier connector.

  2. Measure the voltage and resistance of the wire harness side connector.

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    IG+ (A33-20) - GND (A33-29)
    R-L - L
    Power source (IG)
    Ignition switch OFF
    Below 1V
    IG (A33-20) - GND (A33-29)
    R-L - L
    Power source (IG)
    Ignition switch ON
    10 to 14 V
    GND (A33-29) - Body ground
    L - Body ground
    Ground
    Always
    Below 1 Ω
    ACON (A33-8) - GND (A33-29)
    R-G - L
    A/C switch signal
    Ignition switch ON
    Blower switch OFF
    A/C switch OFF
    Below 1 V
    ACON (A33-8) - GND (A33-29)
    R-G - L
    A/C switch signal
    Ignition switch ON
    Blower switch ON
    A/C switch ON
    10 to 14 V
    IND- (A33-9) - GND (A33-29)
    R-L - L
    A/C indicator light signal
    Ignition switch ON
    Blower switch OFF
    A/C switch OFF
    Below 1 V
    IND- (A33-9) - GND (A33-29)
    R-L - L
    A/C indicator light signal
    Ignition switch ON
    Blower switch ON
    A/C switch ON
    10 to 14 V
    BLW (MHOT) (A33-38) - GND (A33-29)
    R-L - L
    Max. HOT switch signal
    Ignition switch ON
    Temperature control knob: Max HOT
    Below 1 Ω
    BLW (MHOT) (A33-38) - GND (A33-29)
    R-L - L
    Max. HOT switch signal
    Ignition switch ON
    Temperature control knob: except Max HOT
    10 kΩ or higher
    POWHTR (A33-5) - GND (A33-29)
    L-O - L
    Heater switch signal
    Power heater switch ON
    Below 1 Ω
    POWHTR (A33-5) - GND (A33-29)
    L-O - L
    Heater switch signal
    Power heater switch OFF
    10 kΩ or higher
    MGC (A33-19) - GND (A33-29)
    B - L
    Magnet clutch relay signal
    Ignition switch ON
    Blower switch ON
    10 to 14 V
    MGC (A33-19) - GND (A33-29)
    B - L
    Magnet clutch relay signal
    Ignition switch ON
    Blower switch OFF
    Below 1 V
    TAIL (A14-7) - GND (A14-29)
    G - L
    Light control switch signal
    Light control switch ON
    10 to 14 V
    TAIL (A33-7) - GND (A33-29)
    G - L
    Light control switch signal
    Light control switch OFF
    Below 1 V

    1. If the result is not as specified, there may be a malfunction on the wire harness side.

  3. Reconnect the A33 connector.

  4. Measure the voltage and resistance of the connector.

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    PSW (A33-4) - GND (A33-29)
    Y-B - L
    A/C pressure switch signal
    Ignition switch START
    Refrigerant pressure normal: 0.18 MPa (1.9 kgf/cm2, 26 psi) to 3.03 MPa (31.0 kgf/cm2, 440 psi)
    A/C switch ON
    Blower switch ON
    10 to 14 V
    PSW (A33-4) - GND (A33-29)
    Y-B - L
    A/C pressure switch signal
    Ignition switch START
    Refrigerant pressure less than 0.18 MPa (1.9 kgf/cm2, 26 psi) or more than 3.03 MPa (31.0 kgf/cm2, 440 psi)
    A/C switch ON
    Blower switch ON
    Below 1 V
    TE (A33-24) - SG-1 (A33-31)
    G - P
    Evaporator temperature sensor signal
    Ignition switch ON
    Evaporator temperature is 0°C (32°F)
    Temperature control knob: MAX COOL
    2.0 to 2.4 V
    TE (A33-24) - SG-1 (A33-31)
    G - P
    Evaporator temperature sensor signal
    Ignition switch ON
    Evaporator temperature is 15°C (59°F)
    Temperature control knob: MAX COOL
    1.4 to 1.8 V
    SG-1 (A33-31) - Body ground
    P - L
    Ground for evaporator temperature sensor
    Always
    Below 1 Ω
    MGC (A33-19) - GND (A33-29)
    B - L
    Magnet clutch signal
    Ignition switch START
    Magnet clutch is not engaged
    Below 1 V
    MGC (A33-19) - GND (A33-29)
    B - L
    Magnet clutch signal
    Ignition switch START
    Magnet clutch is engaged
    10 to 14 V
    ACT (A33-39) - GND (A33-29)
    R-L - L
    Magnet on permit signal
    Ignition switch START
    A/C switch OFF
    Blower switch OFF
    Below 1 V
    ACT (A33-39) - GND (A33-29)
    R-L - L
    Magnet on permit signal
    Ignition switch START
    A/C switch ON
    Blower switch ON
    10 to 14 V
    AC1 (A33-35) - GND (A33-29)
    Y - L
    Idle-up request signal
    Ignition switch START
    Magnet clutch is not engaged
    10 to 14 V
    AC1 (A33-35) - GND (A33-29)
    Y - L
    Idle-up request signal
    Ignition switch START
    Magnet clutch is engaged
    Below 1.0 V
    BLW (A33-38) - GND (A33-29)
    R-L - L
    Max. HOT switch signal
    Ignition switch ON
    Blower switch ON
    temperature control knob: Max HOT
    Heater switch ON
    Coolant temperature 65°C (149°F)
    10 to 14 V
    BLW (A33-38) - GND (A33-29)
    R-L - L
    Max. HOT switch signal
    Ignition switch ON
    Blower switch ON
    Temperature control knob: except Max HOT
    Heater switch OFF
    Coolant temperature 65°C (149°F)
    Below 1 V
    HEAT (A33-5) - GND (A33-29)
    L-O - L
    Heater switch input signal
    Ignition switch ON
    Blower switch ON
    temperature control knob: Max HOT
    Heater switch ON
    Coolant temperature 65°C (149°F)
    Below 1 V
    HEAT (A33-5) - GND (A33-29)
    L-O - L
    Heater switch input signal
    Ignition switch ON
    Blower switch ON
    Temperature control knob: except Max HOT
    Heater switch OFF
    Coolant temperature 65°C (149°F)
    10 to 14 V
    SWIN (A33-15) - GND (A33-29)
    P - L
    Heater switch indicator light signal
    Ignition switch ON
    Blower switch ON
    temperature control knob: Max HOT
    Heater switch ON
    Coolant temperature 65°C (149°F)
    Below 1 V
    SWIN (A33-15) - GND (A33-29)
    P - L
    Heater switch indicator light signal
    Ignition switch ON
    Blower switch ON
    Temperature control knob: except Max HOT
    Heater switch OFF
    Coolant temperature 65°C (149°F)
    10 to 14 V
    PTCR (A33-26) - GND (A33-29)
    L-W - L
    Heater switch output signal
    Ignition switch ON
    Blower switch ON
    temperature control knob: Max HOT
    Heater switch ON
    Coolant temperature 65°C (149°F)
    10 to 14 V
    PTCR (A33-26) - GND (A33-29)
    L-W - L
    Heater switch output signal
    Ignition switch ON
    Blower switch ON
    Temperature control knob: except Max HOT
    Heater switch OFF
    Coolant temperature 65°C (149°F)
    Below 1 V
    TW (A33-32) - GND (A33-29)
    P - L
    Engine coolant temperature signal
    Ignition switch ON
    Pulse generation
    TACO (A33-33) - GND (A33-29)
    B-W - L
    Tachometer signal
    Engine running
    Pulse generation
    (see waveform 1)
    ALT (A33-37) - GND (A33-29)
    G - L
    Generator signal
    Engine running
    Pulse generation
    PTC1 (A33-3) - GND (A33-29)
    R-W - L
    PTC heater relay signal
    Ignition switch ON
    Blower switch ON
    temperature control knob: Max HOT
    Heater switch ON
    Coolant temperature 65°C (149°F)
    Below 1 V
    PTC1 (A33-3) - GND (A33-29)
    R-W - L
    PTC heater relay signal
    Ignition switch ON
    Blower switch ON
    Temperature control knob: except Max HOT
    Heater switch OFF
    Coolant temperature 65°C (149°F)
    10 to 14 V
    PTC2 (A33-2) - GND (A33-29)
    GR - L
    PTC heater relay signal
    Ignition switch ON
    Blower switch ON
    temperature control knob: Max HOT
    Heater switch ON
    Coolant temperature 65°C (149°F)
    Below 1 V
    PTC2 (A33-2) - GND (A33-29)
    GR - L
    PTC heater relay signal
    Ignition switch ON
    Blower switch ON
    Temperature control knob: except Max HOT
    Heater switch OFF
    Coolant temperature 65°C (149°F)
    10 to 14 V

    1. If the result is not as specified, the A/C amplifier may have a malfunction.



  5. I042330E03
  6. Inspect using an oscilloscope.

    1. Waveform 1 (Reference)
      Item
      Content
      Symbols (Terminal No.)
      TACO (A33-33) - GND (A33-29)
      Tool Setting
      5 V/DIV., 20 msec./DIV.
      Condition
      Engine idling

      HINT:
      As engine speed increases, the wavelength shortens.


CHECK ECM (for 1GR-FE)

G036662E05

  1. Measure the voltage of the connectors.

    HINT:

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    ACT (E13-25) - E01 (E15-7)
    R-L - W-B
    Magnet on permit signal
    Ignition switch START
    A/C switch OFF
    Blower switch OFF
    Below 1 V
    ACT (E13-25) - E01 (E15-7)
    R-L - W-B
    Magnet on permit signal
    Ignition switch START
    A/C switch ON
    Blower switch ON
    10 to 14 V
    AC1 (E13-24) - E01 (E15-7)
    Y - W-B
    Idle-up request signal
    Ignition switch START
    A/C magnet clutch is engaged
    Below 1 V
    AC1 (E13-24) - E01 (E15-7)
    Y - W-B
    Magnet on permit signal
    Ignition switch START
    A/C magnet clutch is not engaged
    10 to 14 V

    If the result is not as specified, the ECM may have a malfunction.


CHECK ECM (for 2TR-FE)

G035135E03

  1. Measure the voltage of the connectors.

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    ACT (E9-25) - E01 (E11-6)
    R-L - W-B
    Magnet on permit signal
    Ignition switch START
    A/C switch OFF
    Blower switch OFF
    Below 1 V
    ACT (E9-25) - E01 (E11-6)
    R-L - W-B
    Magnet on permit signal
    Ignition switch START
    A/C switch ON
    Blower switch ON
    10 to 14 V
    AC1 (E9-24) - E01 (E11-6)
    Y - W-B
    Idle-up request signal
    Ignition switch START
    A/C magnet clutch is engaged
    Below 1 V
    AC1 (E9-24) - E01 (E11-6)
    Y - W-B
    Magnet on permit signal
    Ignition switch START
    A/C magnet clutch is not engaged
    10 to 14 V
    If the result is not as specified, the ECM may have a malfunction.


CHECK ECM (for 1KD-FTV)

A066714E12

  1. Measure the voltage of the connectors.

    Symbols (Terminal No.)
    Wiring Color
    Terminal Description
    Condition
    Specified Condition
    ACT (E5-19) - E01 (E7-7)
    R-L - W-B
    Magnet on permit signal
    Ignition switch START
    A/C switch OFF
    Blower switch OFF
    Below 1 V
    ACT (E5-19) - E01 (E7-7)
    R-L - W-B
    Magnet on permit signal
    Ignition switch START
    A/C switch ON
    Blower switch ON
    10 to 14 V
    AC1 (E5-18) - E01 (E7-7)
    Y - W-B
    Idle-up request signal
    Ignition switch START
    A/C magnet clutch is engaged
    Below 1 V
    AC1 (E5-18) - E01 (E7-7)
    Y - W-B
    Magnet on permit signal
    Ignition switch START
    A/C magnet clutch is not engaged
    10 to 14 V
    THWO (E4-2) - E01 (E7-7)*
    P - W-B
    Water temperature signal
    Ignition switch START
    Pulse generation
    HSW (E4-20) - E01 (E7-7)*
    L-W - W-B
    Heater switch output signal for idle-up
    Ignition switch START
    Heater switch ON
    Blower switch ON
    Temperature control knob: Max HOT
    Engine coolant temperature 65°C (149 °F)
    Below 1 V
    HSW (E4-20) - E01(E7-7)*
    L-W - W-B
    Heater switch output signal for idle-up
    Ignition switch START
    Heater switch OFF
    Blower switch ON
    Temperature control knob: except Max HOT
    Engine coolant temperature 65°C (149 °F)
    10 to 14 V
    TACH (E4-4) - E01 (E7-7)*
    B-W - W-B
    Tachometer signal
    Engine running
    Pulse generation
    (see waveform 1)
    If the result is not as specified, the ECM may have a malfunction.

    HINT:
    *: w/ PTC Heater



  2. I042330E03
  3. Inspect using an oscilloscope (w/PTC heater only)

    1. Waveform 1 (Reference)
      Item
      Content
      Symbols (Terminal No.)
      TACH (E4-4) - E01 (E7-7)
      Tool Setting
      5 V/DIV., 20 msec./DIV.
      Condition
      Engine idling

      HINT:
      As engine speed increases, the wavelength shortens.