COMPRESSOR (for 1KD-FTV) > INSTALLATION |
| 1. ADJUST COMPRESSOR OIL |
When replacing the compressor and magnet clutch with a new one, gradually discharge the refrigerant gas from the service valve, and drain the following amount of oil from the new compressor and magnet clutch before installation.
| 2. INSTALL COOLER COMPRESSOR ASSEMBLY |
![]() |
Install the compressor with the 4 bolts and tighten the bolts in the order shown in the illustration.
Connect the connector.
| 3. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
![]() |
Remove the vinyl tape attached to the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor.
Install the O-ring to the discharge hose.
Connect the discharge hose with the bolt.
| 4. INSTALL SUCTION HOSE SUB-ASSEMBLY |
![]() |
Remove the vinyl tape attached to the hose.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the compressor.
Install the O-ring to the suction hose.
Connect the suction hose with the bolt.
| 5. INSTALL DRIVE BELT |
Rotate the V-ribbed belt tensioner pulley clockwise, and then install the fan and generator V belt.
Check that the indicator mark of the V-ribbed belt tensioner (Click here).
| 6. INSTALL AIR CLEANER ASSEMBLY |
Connect the air cleaner hose.
Install the cleaner with the 2 bolts.
Tighten the hose clamp.
Connect the connector to the mass air flow meter connector.
| 7. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 8. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.
| 9. CHECK FOR LEAKAGE OF REFRIGERANT |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a gas leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.