CONDENSER (for 2TR-FE) > INSTALLATION |
| 1. INSTALL COOLER CONDENSER ASSEMBLY |
![]() |
Install the cooler condenser assembly.
| 2. INSTALL UPPER RADIATOR SUPPORT SUB-ASSEMBLY |
![]() |
Install the upper radiator support sub-assembly with the 7 bolts.
| 3. INSTALL HOOD LOCK ASSEMBLY |
![]() |
Apply MP grease to the sliding areas of the lock.
Connect the hood lock control cable.
Install the hood lock with the 3 bolts.
| 4. INSTALL AIR CONDITIONING TUBE AND ACCESSORY ASSEMBLY |
Remove the vinyl tape attached to the air conditioning tube and accessory assembly and connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the air conditioning tube and accessory assembly joint.
Install the O-ring to the air conditioning tube and accessory assembly.
Install the air conditioning tube and accessory assembly to the cooler condenser with the bolt.
| 5. INSTALL NO. 1 COOLER REFRIGERANT DISCHARGE HOSE |
Remove the vinyl tape attached to the No. 1 cooler refrigerant discharge hose and connecting part of the cooler condenser.
Sufficiently apply compressor oil to a new O-ring and the fitting surface of the No. 1 cooler refrigerant discharge hose joint.
Install the O-ring to the No. 1 cooler refrigerant discharge hose.
Install the No. 1 cooler refrigerant discharge hose to the cooler condenser with the bolt.
| 6. INSTALL FRONT BUMPER COVER |
| 7. CHARGE REFRIGERANT |
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).

| 8. WARM UP ENGINE |
Warm up the engine at less than 1,850 rpm for 2 minutes or more after charging refrigerant.
| 9. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:
![]() |
Using a gas leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the gas leak detector sensor into the unit and perform the test.
Disconnect the connector and leave the pressure switch on for approximately 20 minutes. Bring the gas leak detector close to the pressure switch and perform the test.