AIR CONDITIONING PANEL (for Manual Air Conditioning System) > INSTALLATION |
| 1. CONNECT AIR MIX DAMPER CONTROL CABLE SUB-ASSEMBLY |
![]() |
Attach the 2 claws to connect the air mix control cable sub-assembly.
| 2. CONNECT HEATER CONTROL CABLE SUB-ASSEMBLY |
![]() |
Attach the 2 claws to install the heater control cable sub-assembly.
| 3. CONNECT AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY |
![]() |
Attach the 2 claws to install the air inlet damper control cable sub-assembly.
| 4. INSTALL AIR CONDITIONING CONTROL ASSEMBLY |
Connect the connector and install the air conditioning control assembly.
| 5. INSTALL HEATER CONTROL KNOB |
![]() |
Install the heater control knob as shown in the illustration.
| 6. INSTALL NO. 2 HEATER CONTROL KNOB |
![]() |
Install the No. 2 heater control knob as shown in the illustration.
| 7. INSTALL COOLER SWITCH |
Connect the connector.
Attach the 2 claws to install the cooler switch.
| 8. INSTALL CENTER INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY |
for Manual Air Conditioning System:
Connect the connectors.
Attach the 4 claws to connect the air conditioner control.
Attach the 10 claws and 4 clips to install the center instrument cluster finish panel.
for Automatic Air Conditioning System:
Connect the connectors.
Attach the 8 claws and 4 clips to install the center instrument cluster finish panel.