DTC P2742 Transmission Fluid Temperature Sensor "B" Circuit Low Input |
DTC P2743 Transmission Fluid Temperature Sensor "B" Circuit High Input |
| No. 2 ATF Temperature Sensor State | Detection Condition | Symptom | Recovery Condition |
| Sensor is normal | ATF temperature higher than 150°C (302°F) | ATF temperature warning light remains on | ATF temperature below 135°C (275°F)*1 |
| ATF temperature higher than 130°C (266°F) | Shift point too high | ATF temperature below 110°C (230°F) | |
| When conditions (a) and (b) are satisfied: (a) ATF temperature higher than 130°C (266°F) (b) Engine coolant temperature higher than 95°C (203°F) | Lock-up in 3rd gear*2 | ATF temperature below 110°C (230°F)*1 and engine coolant temperature higher than 95°C (203°F) | |
| Sensor is short-circuited | Any conditions |
| Symptoms still occur |
| Engine coolant temperature higher than 95°C (203°F) | Lock-up in 3rd gear*2 | Symptoms still occur |
| DTC Code | DTC Detection Condition | Trouble Area |
| P2742 | No. 2 ATF temperature sensor resistance is below 25 Ω (0.046 V) for 0.5 sec. or more (1-trip detection logic). |
|
| P2743 | When 15 min. or more have elapsed after the engine is started, No. 2 ATF temperature sensor resistance is higher than 156 kΩ (4.915 V) for 0.5 sec. or more (1-trip detection logic). |
|
| DATA LIST |
Warm up the engine.
Turn the ignition switch off.
Connect the GTS to the DLC3.
Turn the ignition switch to ON.
Turn the GTS on.
Enter the following menus: Powertrain / ECT / Data List.
According to the display on the GTS, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| A/T Oil Temperature 2 | No. 2 ATF temperature sensor value/ Min.: -40.0°C (-40.0°F) Max.: 215.0°C (419.0°F) |
| If the value is -40°C (-40°F) or 215°C (419°F), the No. 2 ATF temperature sensor circuit is open or shorted. |
| Temperature Displayed | Malfunction |
| -40°C (-40°F) | Open circuit |
| 150°C (302°F) or higher | Short circuit |
| 1.INSPECT TRANSMISSION WIRE (NO. 2 ATF TEMPERATURE SENSOR) |
![]() |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 (OT2-) - 9 (OT2+) | Always | 25 Ω to 156 kΩ |
| 1 (OT2-) - Body ground | Always | 10 kΩ or higher |
| 9 (OT2+) - Body ground | Always | 10 kΩ or higher |
| ATF Temperature | Specified Condition |
| 10°C (50°F) | 5 to 8 kΩ |
| 25°C (77°F) | 2.5 to 4.5 kΩ |
| 110°C (230°F) | 0.22 to 0.28 kΩ |
| *a | Component without harness connected (Transmission Wire) |
|
| ||||
| OK | |
| 2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - TCM) |
![]() |
Disconnect the TCM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| T19-24 (THO2) - T19-23 (E2) | Always | 25 Ω to 156 kΩ |
| T19-24 (THO2) - Body ground | Always | 10 kΩ or higher |
| T19-23 (E2) - Body ground | Always | 10 kΩ or higher |
| *a | Rear view of wire harness connector (to TCM) |
|
| ||||
| OK | ||
| ||