Home › ENGINE · 2TR-FE › ENGINE CONTROL SYSTEM › SFI SYSTEM (w/ Secondary Air Injection System)

DTC    P0137    Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2)

for Preparation Click here

HINT:
Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.


DESCRIPTION

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a TWC is used. For the most efficient use of the TWC, the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel level. To help the ECM to deliver accurate air-fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the TWC, and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with the heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-TWC air-fuel ratio is lean (low voltage, i.e. less than 0.45 V).
Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-TWC air-fuel ratio is rich (high voltage, i.e. more than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air-fuel ratio after the TWC is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in the primary air-fuel ratio control.

A088111E02


DTC No.
DTC Detection Conditions
Trouble Areas
P0137
Low voltage (open):
During active air-fuel ratio control, conditions (a) and (b) are met for certain period of time (2 trip detection logic):
(a) Heated oxygen sensor output voltage is less than 0.21 V
(b) Target air-fuel ratio rich
  1. Open in heated oxygen sensor (sensor 2) circuit
  2. Heated oxygen sensor (sensor 2)
  3. Gas leakage from exhaust system

WIRING DIAGRAM


A192076E01


CONFIRMATION DRIVING PATTERN

HINT:
  1. This confirmation driving pattern is used in the following diagnostic troubleshooting inspection procedure when using the intelligent tester.
  2. Performing this confirmation pattern will activate the heated oxygen sensor monitor (the catalyst monitor is performed simultaneously). This is very useful for verifying the completion of a repair.


A112072E01

(a) Connect the intelligent tester to the DLC3.
(b) Turn the ignition switch ON and turn the intelligent tester ON.
(c) Change the ECM from normal mode to check mode using the intelligent tester.
(d) Start the engine.
(e) Allow the engine to idle for 2 minutes.
(f) Warm up the engine until the engine coolant temperature reaches more than 75°C (167°F)
(g) Drive the vehicle between 64 and 113 km/h (40 and 70 mph) for at least 10 minutes.
(h) Stop the vehicle and allow the engine to idle for 20 seconds or more.

HINT:
If a malfunction exists, the MIL will illuminate during step (g).

NOTICE:
If the conditions in this test are not strictly followed, detection of a malfunction will not occur.


INSPECTION PROCEDURE

HINT:
Intelligent tester only:
Malfunctioning areas can be identified by performing the "Control the Injection Volume for A/F Sensor" function provided in the Active Test. The "Control the Injection Volume for A/F Sensor" function can help to determine whether the Air-fuel Ratio (A/F) sensor, heated oxygen (HO2) sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the "Control the Injection Volume for A/F Sensor" operation using intelligent tester.
  1. Connect the intelligent tester to the DLC3.
  2. Start the engine and turn the tester ON.
  3. Warm up the engine at an engine speed of 2,500 rpm for approximately 90 seconds.
  4. On the tester, select the following menu items: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
  5. Perform the "Control the Injection Volume for A/F Sensor" operation with the engine in an idling condition (press the right or left button to change the fuel injection volume).
  6. Monitor the output voltage of the A/F and Heated oxygen sensors (AFS Voltage B1S1 and O2S B1S2) displayed on the tester.

HINT:
  1. The "Control the Injection Volume for A/F Sensor" operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
  2. Each sensor reacts in accordance with increases and decreases in the fuel injection volume.


Standard:

Tester Display
(Sensor)
Injection Volume
Status
Voltage
AFS Voltage B1S1
(A/F)
+12.5%
Rich
Less than 3.0 V
AFS Voltage B1S1
(A/F)
-12.5%
Lean
More than 3.35 V
O2S B1S2
(HO2)
+12.5%
Rich
More than 0.55 V
O2S B1S2
(HO2)
-12.5%
Lean
Less than 0.4 V

NOTICE:
The A/F sensor output has a few seconds of delay and the heated oxygen sensor output has about 20 seconds of delay at maximum.


Case
A/F Sensor (Sensor 1) Output Voltage
HO2 Sensor (Sensor 2) Output Voltage
Main Suspected Trouble Area
1
A150787E08
A151324E01
A150787E08
A150788E01
-
2
A150787E08
A150790E01
A150787E08
A150788E01
  1. A/F sensor
  2. A/F sensor heater
  3. A/F sensor circuit
3
A150787E08
A151324E01
A150787E08
A150790E01
  1. HO2 sensor
  2. HO2 sensor heater
  3. HO2 sensor circuit
4
A150787E08
A150790E01
A150787E08
A150790E01
  1. Injector
  2. Fuel pressure
  3. Gas leak from exhaust system (Air-fuel ratio extremely rich or lean)
The following "Control the Injection Volume for A/F Sensor" procedure enables the technician to check and graph the output voltage of both A/F sensor and heated oxygen sensor.
To display the graph, select the following menu items on the tester: View / Line graph.

HINT:
  1. Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.
  2. A low A/F sensor voltage could be caused by a rich air-fuel mixture. Check the conditions that would cause the engine to run with the rich air-fuel mixture.
  3. A high A/F sensor voltage could be caused by a lean air-fuel mixture. Check the conditions that would cause the engine to run with the lean air-fuel mixture.

1.CHECK ANY OTHER DTCS OUTPUT (IN ADDITION P0137)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester ON.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs.
    Result 
    Display (DTC Output)
    Proceed to
    DTC P0137 is output
    A
    DTC P0137 and other DTCs are output
    B



B
GO TO DTC CHART
A


2.CHECK FOR EXHAUST GAS LEAKAGE
  1. Check for exhaust gas leakage.

    OK:
    No gas leakage.



NG
REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT
OK


3.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)
A062378E22
  1. Disconnect the H5 sensor connector.

  1. Measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    2 (+B) -1 (HT1B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E2)
    Always
    10 kΩ or higher



NG
REPLACE HEATED OXYGEN SENSOR
OK


4.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
G038631E19
  1. Disconnect the H5 heated oxygen sensor connector.

  1. Disconnect the E11 ECM connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance:
    Tester Connection
    Specified Condition
    H5-1 (HT1B) - E11-2 (HT1B)
    H5-3 (OX1B) - E11-25 (OX1B)
    H5-4 (E2) - E11-28 (E2)
    Below 1 Ω
    H5-1 (HT1B) - E11-2 (HT1B) - Body ground
    H5-3 (OX1B) - E11-25 (OX1B) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5.REPLACE HEATED OXYGEN SENSOR
  1. Replace the heated oxygen sensor.


NEXT


6.PERFORM CONFIRMATION DRIVING PATTERN

HINT:
Clear all DTCs prior to performing the confirmation driving pattern.


NEXT


7.CHECK WHETHER DTC OUTPUT RECURS (DTC P0137 IS OUTPUT AGAIN)
  1. Read DTC using the intelligent tester.
    Result 
    Result
    Proceed to
    P0137 is not output again
    A
    P0137 is output again
    B



B
REPLACE AIR FUEL RATIO SENSOR
A

END