Home › ENGINE ยท 2TR-FE › CHARGING › GENERATOR

GENERATOR > REMOVAL

for Preparation Click here



1. PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).



2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



3. REMOVE INTAKE AIR CONNECTOR AND AIR CLEANER ASSEMBLY


A099871E01
  1. Disconnect the vacuum hose.

  1. Disconnect the No. 2 ventilation hose.

  1. Disconnect the MAF meter connector and wire harness clamps.

  1. Loosen the hose clamp and remove the 4 bolts, air cleaner and intake air connector assembly.



4. REMOVE DRIVE BELT


    A099194E01
  1. Use the hexagon-shaped part indicated by the arrow in the illustration to move the tensioner pulley downward and decrease the tension in the drive belt. Then remove the drive belt.

    NOTICE:
    When removing the drive belt, do not use the idle pulley's bolt.

    HINT:
    After removing the drive belt, move the tensioner upward to the maximum amount.



5. REMOVE GENERATOR ASSEMBLY


    A099681E03
  1. Disconnect the terminal cap.

  1. Remove the nut, bolt and generator wire.

  1. Disconnect the generator connector.

  1. Remove the 2 bolts and generator.