DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |

| DTC Code | DTC Detection Condition | Trouble Area |
| P2716 | Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
|

| 1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
![]() |
Disconnect the E19 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 2 (SLT+) - 6 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| 2 (SLT+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| 6 (SLT-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM) |
![]() |
Disconnect the E10 ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| E10-12 (SLT+) - E10-13 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
| E10-12 (SLT+) - Body ground | 20°C (68°F) | 10 kΩ or higher |
| E10-13 (SLT-) - Body ground | 20°C (68°F) | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 3.INSPECT SHIFT SOLENOID VALVE SLT |
![]() |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
![]() |
Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.
![]() |
| Item | Content |
| Tester Connection | E10-12 (SLT+) - E10-13 (SLT-) |
| Tool Setting | 5 V/DIV., 1 msec./DIV. |
| Condition | Engine is idling |
|
| ||||
| OK | ||
| ||