Home › TRANSMISSION · A343E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FBE)

DTC    P0973    Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)

DTC    P0974    Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)

DTC    P0976    Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)

DTC    P0977    Shift Solenoid "B" Control Circuit High (Shift Solenoid Valve S2)

for Preparation Click here


DESCRIPTION

Shifting from 1st to 4th is performed in combination with the on and off operation of the shift solenoid valves S1 and S2 controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be operated safely (fail-safe function).
Fail-safe function:
If either of the shift solenoid valve circuits develops an open or short, the ECM turns the other shift solenoid on and off to shift to the gear positions shown in the table below. The ECM also turns the shift solenoid valve SL off at the same time. If both solenoids are malfunctioning, electronic hydraulic control does not operate and must be performed manually. Manual shifting as shown in the following table must be performed.
In case of a short circuit, the ECM stops sending current to the circuit.

Position
Normal
Shift Solenoid Valve S1 Malfunctioning
Shift Solenoid Valve S2 Malfunctioning
Both Solenoids Malfunctioning
Solenoid valve
Gear
Solenoid valve
Gear
Solenoid valve
Gear
Gear when shift lever is manually operated
S1
S2
S1
S2
S1
S2
D
ON
OFF
1st
X
OFF
O/D
ON
X
1st
O/D
ON
ON
2nd
X
ON
3rd
ON
X
1st
O/D
OFF
ON
3rd
X
ON
3rd
OFF
X
O/D
O/D
OFF
OFF
O/D
X
OFF
O/D
OFF
X
O/D
O/D
3
ON
OFF
1st
X
OFF
O/D
ON
X
1st
O/D
ON
ON
2nd
X
ON
3rd
ON
X
1st
O/D
OFF
ON
3rd
X
ON
3rd
OFF
X
3rd
O/D
2
ON
OFF
1st
X
ON
3rd
ON
X
1st
3rd
ON
ON
2nd
X
ON
3rd
OFF
X
3rd
3rd
L
ON
OFF
1st
X
OFF
O/D
ON
X
1st
1st

HINT:
X: Malfunction


DTC No.
DTC Detection Condition
Trouble Area
P0973
ECM detects short in solenoid valve S1 circuit 4 times when solenoid valve S1 is operated (1 trip detection logic)
  1. Short in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM
P0974
ECM detects open in solenoid valve S1 circuit 4 times when solenoid valve S1 is not operated (1 trip detection logic)
  1. Open in shift solenoid valve S1 circuit
  2. Shift solenoid valve S1
  3. ECM
P0976
ECM detects short in solenoid valve S2 circuit 4 times when solenoid valve S2 is operated (1 trip detection logic)
  1. Short in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM
P0977
ECM detects open in solenoid valve S2 circuit 4 times when solenoid valve S2 is not operated (1 trip detection logic)
  1. Open in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM

MONITOR DESCRIPTION

The ECM controls gear shift by turning the shift solenoid valves on/off. When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem, illuminates the MIL and stores a DTC.
The ECM performs the fail-safe function and turns the normally functioning shift solenoid valve on/off.
In case of an open or short circuit, the ECM stops sending current to the circuit.

WIRING DIAGRAM


C169746E11


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE S1/S2)


    C170576E04
  1. Disconnect the E19 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    4 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω
    8 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω



NG
Go to step 3
OK


2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)


    C214336E23
  1. Disconnect the E21 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E21-21 (S1) - Body ground
    20°C (68°F)
    11 to 15 Ω
    E21-22 (S2) - Body ground
    20°C (68°F)
    11 to 15 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE S1/S2
C169051E02
  1. Remove the shift solenoid valve S1/S2.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body
    20°C (68°F)
    11 to 15 Ω
    Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

  1. Check the operating noise of the solenoid valve.

    OK:
    Solenoid makes operating noise.



NG
REPLACE SHIFT SOLENOID VALVE S1/S2
OK

REPAIR OR REPLACE TRANSMISSION WIRE