Home › TRANSMISSION · A343E AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM (for 2TR-FBE)

DTC    P2769    Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

DTC    P2770    Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

for Preparation Click here


DESCRIPTION

The shift solenoid valve SL is turned on and off by signals from the ECM to control the hydraulic pressure acting on the lock-up relay valve, which then controls the operation of the lock-up clutch.

DTC No.
DTC Detection Condition
Trouble Area
P2769
ECM detects short in shift solenoid valve SL circuit (once) when shift solenoid valve SL is operated (2 trip detection logic)
  1. Short in shift solenoid valve SL circuit
  2. Shift solenoid valve SL
  3. ECM
P2770
ECM detects open in shift solenoid valve SL circuit (once) when shift solenoid valve SL is not operated (2 trip detection logic)
  1. Open in shift solenoid valve SL circuit
  2. Shift solenoid valve SL
  3. ECM
Fail-safe function:
If the ECM detects a malfunction, it turns the shift solenoid valve SL off.

MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on engine rpm, engine load, engine temperature, vehicle speed, transmission temperature, and shift position selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) to the input rpm (NC0). The ECM calculates the actual transmission gear by comparing the input rpm (NC0) to the output rpm (SP2). When conditions are appropriate, the ECM requests "lock-up" by applying control voltage to the shift solenoid valve SL. When the shift solenoid valve SL is opened, the shift solenoid valve SL applies pressure to the lock-up relay valve and locks the torque converter clutch. If the ECM detects an open or short in the shift solenoid valve SL circuit, the ECM interprets this as a fault in the shift solenoid valve SL or its circuit. The ECM will illuminate the MIL and store a DTC.

WIRING DIAGRAM


C229330E02


INSPECTION PROCEDURE

1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SL)


    C170576E11
  1. Disconnect the E19 transmission wire connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    7 (SL) - Body ground
    20°C (68°F)
    11 to 15 Ω



NG
Go to step 3
OK


2.CHECK WIRE HARNESS (TRANSMISSION WIRE - ECM)


    C214336E25
  1. Disconnect the E21 ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    E21-19 (SL) - Body ground
    20°C (68°F)
    11 to 15 Ω



NG
REPAIR OR REPLACE HARNESS AND CONNECTOR
OK

REPLACE ECM 

3.INSPECT SHIFT SOLENOID VALVE SL
C155226E06
  1. Remove the shift solenoid valve SL.

  1. Measure the resistance according to the value(s) in the table below.

    Tester Connection
    Condition
    Specified Condition
    Shift solenoid valve SL connector terminal - Shift solenoid valve SL body
    20°C (68°F)
    11 to 15 Ω

  1. Connect the battery's positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

  1. Check the operating noise of the solenoid valve.

    OK:
    Solenoid makes operating noise.



NG
REPLACE SHIFT SOLENOID VALVE SL
OK

REPAIR OR REPLACE TRANSMISSION WIRE