Home › ENGINE ยท 1GR-FE › CHARGING › GENERATOR (for BOSCH Made)

GENERATOR (for BOSCH Made) > REMOVAL

for Preparation Click here



1. PRECAUTION

NOTICE:
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).



2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).



3. REMOVE V-BANK COVER
  1. Remove the 2 nuts and cover.



4. REMOVE DRIVE BELT


A076441E01
  1. While releasing the belt tension by turning the belt tensioner counterclockwise, remove the V-ribbed belt from the belt tensioner.



5. REMOVE GENERATOR ASSEMBLY


A194920
  1. Disconnect the terminal cap.

  1. Remove the 2 bolts, nut and generator wire.

  1. Disconnect the generator connector.

  1. Remove the 2 bolts and generator.