Home › ENGINE · 2KD-FTV › EMISSION CONTROL › EGR VALVE

EGR VALVE > INSPECTION

for Preparation Click here



1. INSPECT ELECTRIC EGR CONTROL VALVE ASSEMBLY


    A099571E02
  1. Inspect the electric EGR control valve.

    1. When a vacuum of 27 kPa (200 mmHg, 7.88 in.Hg) is applied to the diaphragm chamber, check that the shaft rises and air flows out.

    2. While maintaining the above conditions, check that there are no leaks and that the shaft stays in position.

    3. Check that the valve does not have heavy carbon deposits and is not stuck.
      If the result is not as specified, replace the electric EGR control valve assembly.



  1. Inspect the EGR valve position sensor.



      A085764E07
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 (VC) - 2 (E2)
      20°C (68°F)
      2.8 to 7.8 kΩ

      Text in Illustration 
      *a
      Component without harness connected
      (Electric EGR Control Valve)
      If the result is not as specified, replace the electric EGR control valve assembly.

  1. Create a vacuum in the diaphragm chamber.



    A099572E08
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    3 (EGLS) - 2 (E2)
    20°C (68°F)
    EGR valve is fully opened
    2.0 to 7.0 kΩ
    20°C (68°F)
    EGR valve is fully closed
    0.1 to 2.5 kΩ

    Text in Illustration 
    *a
    Component without harness connected
    (Electric EGR Control Valve)

    HINT:
    The resistance increases in proportion to the opening amount of the EGR valve.

    If the result is not as specified, replace the electric EGR control valve assembly.