Home › ENGINE · 1KD-FTV › EMISSION CONTROL › VACUUM SWITCHING VALVE (w/o Glow Plug Controller)

VACUUM SWITCHING VALVE (w/o Glow Plug Controller) > INSPECTION

for Preparation Click here



1. INSPECT VACUUM SWITCHING VALVE NO.1 (for EGR Cut)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    37 to 44 Ω
    1 - Body ground
    2 - Body ground
    10 kΩ or higher

    If the result is not as specified, replace the vacuum switching valve.



  1. Check operation of the vacuum switching valve.



      A151248E07
    1. Attach a vacuum pump to port E and check that vacuum does not flow from the filter to port E.



    2. A151249E06
    3. Apply battery voltage across terminals 1 and 2.

    4. Attach a vacuum pump to port E and check that vacuum flows from the filter to port E.
      If the result is not as specified, replace the vacuum switching valve.



2. INSPECT VACUUM SWITCHING VALVE (for EGR Bypass Valve)
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    37 to 44 Ω
    1 - Body ground
    2 - Body ground
    10 kΩ or higher

    If the result is not as specified, replace the vacuum switching valve.



    A222591E04
  1. Check operation of the vacuum switching valve.

    1. When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.



    2. A222592E04
    3. Apply battery voltage across terminals 1 and 2.

    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the vacuum switching valve.