VACUUM SWITCHING VALVE (w/o Glow Plug Controller) > INSPECTION |
| 1. INSPECT VACUUM SWITCHING VALVE NO.1 (for EGR Cut) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
| 1 - Body ground 2 - Body ground | 10 kΩ or higher |
Check operation of the vacuum switching valve.
![]() |
Attach a vacuum pump to port E and check that vacuum does not flow from the filter to port E.
![]() |
Apply battery voltage across terminals 1 and 2.
Attach a vacuum pump to port E and check that vacuum flows from the filter to port E.
If the result is not as specified, replace the vacuum switching valve.
| 2. INSPECT VACUUM SWITCHING VALVE (for EGR Bypass Valve) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 37 to 44 Ω |
| 1 - Body ground 2 - Body ground | 10 kΩ or higher |
![]() |
Check operation of the vacuum switching valve.
When a vacuum of 67 kPa (500 mmHg, 19.7 in.Hg) is applied to port F, check that air flows from port E to the filter.
![]() |
Apply battery voltage across terminals 1 and 2.
Check that air flows from port E to port F.
If the result is not as specified, replace the vacuum switching valve.