Home › ENGINE · 2TR-FBE › EMISSION CONTROL › AIR FUEL RATIO SENSOR

AIR FUEL RATIO SENSOR > INSPECTION

for Preparation Click here



1. INSPECT AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)


  1. Check the resistance.



      A112089E10
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 (HA1A) - 2 (+B)
      20°C (68°F)
      1.8 to 3.4 Ω
      1 (HA1A) - 4 (A1A-)
      Always
      10 kΩ or higher

      If the result is not as specified, replace the air fuel ratio sensor.