Home › ENGINE · 2TR-FE › EMISSION CONTROL › HEATED OXYGEN SENSOR (w/o Secondary Air Injection System)

HEATED OXYGEN SENSOR (w/o Secondary Air Injection System) > INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 1)


    A112088E02
  1. Measure the resistance between terminals 1 (HT1A) and 2 (+B) of the sensor.

    Standard resistance:
    5 to 10 Ω at 20°C (68°F)

    If the result is not as specified, replace the heated oxygen sensor.