PURGE VALVE > INSPECTION |
| 1. INSPECT PURGE VSV |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 26 to 30 Ω |
| 1 - Body ground | Always | 10 MΩ or higher |
| 2 - Body ground |
![]() |
Check operation of the purge VSV.
Check that air does not flow from port E to port F.
![]() |
Apply battery voltage across terminals 1 and 2.
Check that air flows from port E to port F.
If the result is not as specified, replace the purge VSV.