Home › ENGINE · 2TR-FBE › EMISSION CONTROL › PURGE VALVE

PURGE VALVE > INSPECTION

for Preparation Click here



1. INSPECT PURGE VSV
  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    26 to 30 Ω
    1 - Body ground
    Always
    10 MΩ or higher
    2 - Body ground

    HINT:
    When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C.

    If the result is not as specified, replace the purge VSV.



    A099532E04
  1. Check operation of the purge VSV.

    1. Check that air does not flow from port E to port F.



    2. A110272E01
    3. Apply battery voltage across terminals 1 and 2.

    4. Check that air flows from port E to port F.
      If the result is not as specified, replace the purge VSV.