FUEL SUPPLY PUMP (w/ Glow Plug Controller) > INSPECTION |
| 1. INSPECT FUEL SUPPLY PUMP ASSEMBLY |
Inspect the suction control valve.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 1.9 to 2.3 Ω |