Home › ENGINE · 1GR-FE › EMISSION CONTROL › HEATED OXYGEN SENSOR

HEATED OXYGEN SENSOR > ON-VEHICLE INSPECTION

for Preparation Click here



1. INSPECT HEATED OXYGEN SENSOR


A120266E01
  1. Using an ohmmeter, measure the resistance of the sensor.

    Standard resistance:
    Tester Connection
    Specified Condition
    1 (HT1B) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT1B) - 4 (E2)
    10 kΩ or higher
    1 (HT2B) - 2 (+B)
    11 to 16 Ω at 20°C (68°F)
    1 (HT2B) - 4 (E2)
    10 kΩ or higher

    If the result is not as specified, replace the sensor.