INTAKE AIR TEMPERATURE SENSOR (w/ Glow Plug Controller) > INSPECTION |
| 1. INSPECT INTAKE AIR TEMPERATURE SENSOR |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| 1 - 2 | 20°C (68°F) | 2.21 to 2.65 kΩ |
| *1 | Resistance kΩ |
| *2 | Temperature °C(°F) |
| *3 | Acceptable Range |
| *a | Component without harness connected (Intake Air Temperature Sensor) |